Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,030
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0101 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $665 | $200 | Implemented |
TA0101 # 10 Y:2005 | 10 | 2005 | INSULATE BARE EQUIPMENT | $255 | $360 | Implemented |
CO0574 # 08 Y:2005 | 08 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,410 | $1,420 | Not Implemented |
CO0574 # 06 Y:2005 | 06 | 2005 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $450 | $110 | Not Implemented |
SU0218 # 10 Y:2005 | 10 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,025 | $15,000 | Not Implemented |
CO0573 # 13 Y:2005 | 13 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $530 | $1,600 | Not Implemented |
CO0573 # 09 Y:2005 | 09 | 2005 | USE OPTIMUM THICKNESS INSULATION | $3,590 | $5,150 | Not Implemented |
UF0369 # 07 Y:2005 | 07 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $5,189 | $5,000 | Not Implemented |
WI0498 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $45,520 | $17,500 | Not Implemented |
UF0369 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $21,928 | $477 | Implemented |
LE0220 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $594 | $450 | Implemented |
OR0487 # 03 Y:2005 | 03 | 2005 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $39,000 | $16,400 | Not Implemented |
OR0487 # 04 Y:2005 | 04 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,600 | $23,000 | Not Implemented |
OK0715 # 07 Y:2005 | 07 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $472 | $1,000 | Not Implemented |
UD0726 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $19,788 | $4,000 | Implemented |
SF0312 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $6,723 | $3,300 | Not Implemented |
SF0312 # 02 Y:2005 | 02 | 2005 | COVER OPEN TANKS | $1,722 | $0 | Implemented |
UD0726 # 11 Y:2005 | 11 | 2005 | COVER OPEN TANKS | $4,429 | $1,200 | Implemented |
UM0289 # 02 Y:2005 | 02 | 2005 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $56,272 | $85,815 | Not Implemented |
UM0289 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $164,291 | $74,114 | Implemented |
UD0726 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $157,981 | $295,540 | Not Implemented |
UD0726 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $93,662 | $72,100 | Implemented |
UD0726 # 03 Y:2005 | 03 | 2005 | USE OPTIMUM THICKNESS INSULATION | $113,135 | $17,165 | Not Implemented |
UM0289 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $37,184 | $11,610 | Implemented |
UM0289 # 05 Y:2005 | 05 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $9,600 | $1,400 | Implemented |