Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,004
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0278 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,116 | $2,200 | Implemented |
MA0571 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $46,372 | $49,355 | Implemented |
IA0361 # 04 Y:2005 | 04 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,960 | $1,114 | Implemented |
IC0095 # 09 Y:2005 | 09 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,010 | $3,168 | Not Implemented |
IC0095 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $16,405 | $50,000 | Not Implemented |
IC0095 # 01 Y:2005 | 01 | 2005 | USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC | $30,106 | $55,000 | Not Implemented |
IC0095 # 07 Y:2005 | 07 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $1,812 | $2,700 | Implemented |
IC0095 # 06 Y:2005 | 06 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,852 | $9,142 | Implemented |
IC0095 # 03 Y:2005 | 03 | 2005 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $116,731 | $400,000 | Not Implemented |
AS0396 # 03 Y:2005 | 03 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $107 | $50 | Not Implemented |
WI0487 # 11 Y:2005 | 11 | 2005 | COVER OPEN TANKS | $1,108 | $360 | Not Implemented |
WI0487 # 10 Y:2005 | 10 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,165 | $3,000 | Not Implemented |
OK0703 # 01 Y:2005 | 01 | 2005 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $37,468 | $34,300 | Not Implemented |
UD0713 # 02 Y:2005 | 02 | 2005 | USE OPTIMUM TEMPERATURE | $64,754 | $2,500 | Not Implemented |
UD0713 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,868 | $22,600 | Not Implemented |
UM0277 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,729 | $3,000 | Not Implemented |
NC0312 # 01 Y:2005 | 01 | 2005 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $6,776 | $6,516 | Not Implemented |
NC0312 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,325 | $2,286 | Implemented |
WI0486 # 01 Y:2005 | 01 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $20,351 | $18,000 | Not Implemented |
SF0301 # 04 Y:2005 | 04 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $11,812 | $1,220 | Not Implemented |
LM0091 # 02 Y:2005 | 02 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,029 | $683 | Implemented |
LM0091 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $764 | $240 | Implemented |
WV0309 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $9,618 | $1,147 | Implemented |
WV0309 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,646 | $232 | Implemented |
MI0099 # 07 Y:2005 | 07 | 2005 | USE MINIMUM STEAM OPERATING PRESSURE | $200 | $115 | Implemented |