Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0005 # 12 Y:2001 12 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $1,855 $277 Implemented
TA0005 # 13 Y:2001 13 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $1,580 $826 Implemented
UD0618 # 04 Y:2001 04 2001 INSTALL / REPAIR INSULATION ON STEAM LINES $8,474 $6,280 Implemented
TA0005 # 07 Y:2001 07 2001 INSULATE BARE EQUIPMENT $14,688 $20,194 Implemented
TA0005 # 14 Y:2001 14 2001 INSULATE BARE EQUIPMENT $258 $249 Not Implemented
OK0612 # 05 Y:2001 05 2001 REPAIR AND ELIMINATE STEAM LEAKS $1,650 $720 Implemented
TA0005 # 04 Y:2001 04 2001 REPAIR AND ELIMINATE STEAM LEAKS $31,880 $1,080 Implemented
TA0005 # 02 Y:2001 02 2001 INCREASE AMOUNT OF CONDENSATE RETURNED $55,066 $8,241 n/a
WI0395 # 05 Y:2001 05 2001 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $2,257 $6,000 Implemented
UD0618 # 09 Y:2001 09 2001 INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER $1,779 $5,000 Not Implemented
WI0395 # 06 Y:2001 06 2001 RECOVER WASTE HEAT FROM EQUIPMENT $1,627 $500 Not Implemented
SD0276 # 05 Y:2001 05 2001 RECOVER WASTE HEAT FROM EQUIPMENT $8,279 $10,000 Not Implemented
SD0276 # 04 Y:2001 04 2001 INSULATE BARE EQUIPMENT $419 $250 Not Implemented
BD0183 # 03 Y:2001 03 2001 REPAIR AND ELIMINATE STEAM LEAKS $1,710 $950 Not Implemented
UM0186 # 03 Y:2001 03 2001 INSULATE BARE EQUIPMENT $7,700 $700 n/a
UM0186 # 04 Y:2001 04 2001 RECOVER WASTE HEAT FROM EQUIPMENT $1,100 $500 n/a
BD0186 # 02 Y:2001 02 2001 RECOVER WASTE HEAT FROM EQUIPMENT $924 $1,118 Not Implemented
SU0116 # 03 Y:2001 03 2001 INSULATE BARE EQUIPMENT $7,323 $979 Implemented
GT0710 # 08 Y:2001 08 2001 INSULATE BARE EQUIPMENT $560 $275 Not Implemented
GT0710 # 04 Y:2001 04 2001 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,125 $3,600 Not Implemented
BD0185 # 04 Y:2001 04 2001 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $5,279 $500 Implemented
LE0107 # 06 Y:2001 06 2001 USE OPTIMUM THICKNESS INSULATION $246 $350 Implemented
SD0274 # 09 Y:2001 09 2001 USE OPTIMUM TEMPERATURE $4,364 $0 Implemented
SD0274 # 01 Y:2001 01 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $126,144 $15,000 n/a
CO0482 # 02 Y:2001 02 2001 RECOVER WASTE HEAT FROM EQUIPMENT $1,800 $700 Not Implemented