Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,000
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0160 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,060 | $2,500 | Not Implemented |
KU0539 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $163,360 | $135,000 | Not Implemented |
KU0539 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $44,700 | $30,000 | Not Implemented |
SF0191 # 01 Y:2000 | 01 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,345 | $4,320 | Not Implemented |
UD0596 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,221 | $1,200 | Implemented |
UM0163 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $2,100 | $200 | Not Implemented |
UM0163 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $10,078 | $10,000 | Not Implemented |
UM0163 # 09 Y:2000 | 09 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,997 | $90,000 | Implemented |
KU0539 # 03 Y:2000 | 03 | 2000 | USE OPTIMUM TEMPERATURE | $15,700 | $20,000 | Implemented |
SF0191 # 03 Y:2000 | 03 | 2000 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $9,529 | $32,232 | Not Implemented |
UM0163 # 08 Y:2000 | 08 | 2000 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $14,512 | $60,000 | Not Implemented |
DS0164 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,164 | $806 | Implemented |
MA0460 # 04 Y:2000 | 04 | 2000 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $5,388 | $13,800 | Implemented |
DS0164 # 04 Y:2000 | 04 | 2000 | USE OPTIMUM THICKNESS INSULATION | $155 | $478 | Implemented |
OD0161 # 01 Y:2000 | 01 | 2000 | INSULATE BARE EQUIPMENT | $2,365 | $5,892 | Not Implemented |
OD0161 # 04 Y:2000 | 04 | 2000 | REPAIR AND ELIMINATE STEAM LEAKS | $1,013 | $1,360 | Not Implemented |
OD0161 # 05 Y:2000 | 05 | 2000 | REPAIR OR REPLACE STEAM TRAPS | $2,084 | $700 | Not Implemented |
UM0162 # 03 Y:2000 | 03 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,628 | $10,800 | Implemented |
UM0162 # 06 Y:2000 | 06 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,858 | $36,000 | Implemented |
DS0165 # 03 Y:2000 | 03 | 2000 | USE OPTIMUM THICKNESS INSULATION | $494 | $275 | Not Implemented |
WI0375 # 09 Y:2000 | 09 | 2000 | USE OPTIMUM THICKNESS INSULATION | $1,052 | $1,084 | Not Implemented |
SD0247 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,628 | $3,000 | Not Implemented |
SD0247 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $570 | $1,030 | Not Implemented |
UF0249 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,950 | $25,000 | Not Implemented |
SD0247 # 01 Y:2000 | 01 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $11,396 | $8,250 | Not Implemented |