Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0167 # 08 Y:1999 08 1999 INSULATE FEEDWATER TANK $601 $1,327 Not Implemented
SF0167 # 01 Y:1999 01 1999 REPAIR AND ELIMINATE STEAM LEAKS $9,860 $175 Not Implemented
SF0167 # 02 Y:1999 02 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $2,924 $0 Not Implemented
SF0167 # 04 Y:1999 04 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $9,607 $5,759 Not Implemented
SF0167 # 07 Y:1999 07 1999 INCREASE AMOUNT OF CONDENSATE RETURNED $5,150 $8,430 Not Implemented
SD0223 # 01 Y:1999 01 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,581 $7,800 Not Implemented
NV0128 # 01 Y:1999 01 1999 INSULATE BARE EQUIPMENT $21,114 $38,248 Implemented
TN0656 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $2,020 $3,560 Not Implemented
HO0202 # 03 Y:1999 03 1999 USE OPTIMUM THICKNESS INSULATION $3,266 $1,190 Not Implemented
NV0127 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $123 $222 Not Implemented
DS0140 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $416 $25 Not Implemented
DS0141 # 01 Y:1999 01 1999 PREHEAT COMBUSTION AIR WITH WASTE HEAT $10,285 $24,040 Implemented
DS0138 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $242 $110 Not Implemented
NC0161 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,160 $500 Not Implemented
MA0437 # 04 Y:1999 04 1999 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $2,225 $300 Implemented
MA0437 # 01 Y:1999 01 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $17,316 $3,000 Not Implemented
MA0437 # 02 Y:1999 02 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $8,292 $1,892 Not Implemented
NC0163 # 02 Y:1999 02 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,614 $1,600 Implemented
NC0163 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $19,985 $35,000 Not Implemented
NC0163 # 04 Y:1999 04 1999 COVER OPEN TANKS $24,515 $21,000 Not Implemented
AM0350 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $1,130 $670 Implemented
KU0515 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $820 $2,540 Not Implemented
TN0659 # 07 Y:1999 07 1999 INSULATE BARE EQUIPMENT $590 $131 Not Implemented
TN0659 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $4,642 $1,860 Implemented
OK0577 # 07 Y:1999 07 1999 INSULATE BARE EQUIPMENT $784 $3,820 Implemented