Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
563
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KG0073 # 08 Y:1996 | 08 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,072 | $4,550 | Not Implemented |
GT0597 # 01 Y:1996 | 01 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $9,934 | $5,000 | Not Implemented |
NV0074 # 06 Y:1996 | 06 | 1996 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $12,900 | $3,600 | Not Implemented |
UD0507 # 03 Y:1996 | 03 | 1996 | USE MINIMUM SAFE OVEN VENTILATION | $1,228 | $5,000 | Implemented |
GT0606 # 04 Y:1996 | 04 | 1996 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $32,500 | $40,000 | Not Implemented |
GT0606 # 06 Y:1996 | 06 | 1996 | COVER OPEN TANKS | $7,420 | $10,000 | Implemented |
GT0606 # 03 Y:1996 | 03 | 1996 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $9,060 | $1,000 | Implemented |
UD0508 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $101,584 | $40,000 | Implemented |
ME0205 # 08 Y:1996 | 08 | 1996 | INSULATE BARE EQUIPMENT | $196 | $270 | Implemented |
ME0205 # 09 Y:1996 | 09 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $11,040 | $200 | Implemented |
ME0205 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $1,004 | $2,112 | Not Implemented |
ME0205 # 07 Y:1996 | 07 | 1996 | INSULATE BARE EQUIPMENT | $244 | $38 | Implemented |
HO0139 # 05 Y:1996 | 05 | 1996 | USE OPTIMUM TEMPERATURE | $2,290 | $3,000 | Implemented |
AR0097 # 04 Y:1996 | 04 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $25,240 | $20,000 | Not Implemented |
HO0139 # 04 Y:1996 | 04 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,870 | $1,129 | Not Implemented |
OD0075 # 04 Y:1996 | 04 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $4,186 | $5,691 | Implemented |
AR0104 # 07 Y:1996 | 07 | 1996 | INSULATE BARE EQUIPMENT | $307 | $100 | Implemented |
OD0075 # 02 Y:1996 | 02 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,096 | $5,800 | Not Implemented |
WI0285 # 04 Y:1996 | 04 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,042 | $3,100 | Not Implemented |
UF0165 # 04 Y:1996 | 04 | 1996 | CLEAN CONDENSER TUBES | $19,869 | $0 | Implemented |
NV0072 # 08 Y:1996 | 08 | 1996 | INSULATE BARE EQUIPMENT | $6,756 | $890 | Implemented |
MS0075 # 03 Y:1996 | 03 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,115 | $3,350 | Not Implemented |
CO0378 # 04 Y:1996 | 04 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,770 | $3,010 | Not Implemented |
MS0075 # 02 Y:1996 | 02 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,676 | $5,365 | Not Implemented |
UM0074 # 04 Y:1996 | 04 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,903 | $4,000 | Not Implemented |