Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

498

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0439 # 03 Y:2013 03 2013 RECOVER WASTE HEAT FROM EQUIPMENT $3,900 $1,000 Implemented
IP0020 # 05 Y:2013 05 2013 RECOVER WASTE HEAT FROM EQUIPMENT $4,867 $625 Not Implemented
DL0119 # 02 Y:2013 02 2013 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $45,282 $138,000 Not Implemented
DL0118 # 01 Y:2013 01 2013 INSULATE BARE EQUIPMENT $13,600 $800 Not Implemented
DL0118 # 08 Y:2013 08 2013 INSULATE BARE EQUIPMENT $2,400 $330 Not Implemented
DL0118 # 07 Y:2013 07 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $4,362 $4,680 Not Implemented
UA3031 # 05 Y:2013 05 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $85 $609 Not Implemented
UA3031 # 04 Y:2013 04 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $174 $3,355 Not Implemented
BD0438 # 15 Y:2013 15 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $286 $325 Implemented
BD0438 # 07 Y:2013 07 2013 REPAIR OR REPLACE STEAM TRAPS $42,432 $1,600 Implemented
UA0112 # 03 Y:2013 03 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $1,177 $878 Implemented
MA0721 # 06 Y:2013 06 2013 REPAIR AND ELIMINATE STEAM LEAKS $2,358 $1,120 Implemented
MA0721 # 09 Y:2013 09 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $1,465 $1,650 Not Implemented
AM0648 # 11 Y:2013 11 2013 INSULATE BARE EQUIPMENT $101 $308 Not Implemented
MI0253 # 01 Y:2013 01 2013 UTILIZE A LESS EXPENSIVE COOLING METHOD $174,761 $506,800 Not Implemented
DL0117 # 04 Y:2013 04 2013 RECOVER WASTE HEAT FROM EQUIPMENT $138,552 $277,104 Not Implemented
UM0437 # 09 Y:2013 09 2013 RECOVER WASTE HEAT FROM EQUIPMENT $4,800 $1,500 Not Implemented
MA0720 # 04 Y:2013 04 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,238 $10,000 Implemented
MI0251 # 10 Y:2013 10 2013 INSULATE BARE EQUIPMENT $5,765 $3,960 Not Implemented
MI0251 # 09 Y:2013 09 2013 INSULATE BARE EQUIPMENT $6,625 $4,623 Not Implemented
MI0251 # 02 Y:2013 02 2013 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $34,598 $56,000 Not Implemented
UD0894 # 07 Y:2013 07 2013 INSULATE BARE EQUIPMENT $142 $350 Implemented
UD0894 # 05 Y:2013 05 2013 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,638 $10,000 Not Implemented
WM0036 # 04 Y:2013 04 2013 INSULATE BARE EQUIPMENT $1,540 $5,355 Not Implemented
UM0436 # 02 Y:2013 02 2013 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $24,443 $12,800 Not Implemented