Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,061

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KS2427 # 04 Y:2024 04 2024 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $69,076 $156,917 n/a
UF0611 # 03 Y:2024 03 2024 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $30,134 $5,900 n/a
UF0611 # 04 Y:2024 04 2024 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $26,100 $0 n/a
UF0610 # 04 Y:2024 04 2024 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $9,119 $36,000 n/a
UL2402 # 05 Y:2024 05 2024 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $176,163 $90,792 n/a
MI0438 # 08 Y:2024 08 2024 UTILIZE A LESS EXPENSIVE COOLING METHOD $2,139 $40 n/a
UU0242 # 05 Y:2024 05 2024 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,004 $11,422 n/a
UU0242 # 06 Y:2024 06 2024 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $21,730 $82,100 n/a
UD1078 # 04 Y:2024 04 2024 UTILIZE A LESS EXPENSIVE COOLING METHOD $204 $550 n/a
UD1078 # 03 Y:2024 03 2024 UTILIZE A LESS EXPENSIVE COOLING METHOD $847 $700 n/a
LE0555 # 09 Y:2024 09 2024 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $43,046 $90,000 n/a
DL0236 # 06 Y:2024 06 2024 UTILIZE A LESS EXPENSIVE COOLING METHOD $4,131 $0 n/a
UU0243 # 06 Y:2024 06 2024 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,800 $6,300 n/a
IC0296 # 09 Y:2024 09 2024 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $62,421 $0 n/a
LE0557 # 06 Y:2024 06 2024 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $291,977 $600,000 n/a
UL2316 # 02 Y:2023 02 2023 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $73,247 $137,300 n/a
UU0240 # 01 Y:2024 01 2024 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $10,047 $10,320 n/a
KS2324 # 07 Y:2023 07 2023 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $57,559 $312,824 n/a
UD1074 # 02 Y:2024 02 2024 UTILIZE A LESS EXPENSIVE COOLING METHOD $12,621 $12,700 n/a
UW2319 # 04 Y:2023 04 2023 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $11,443 $68,000 n/a
NL0090 # 04 Y:2023 04 2023 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,454 $1,764 n/a
UU0239 # 03 Y:2024 03 2024 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $9,905 $9,905 n/a
UL2314 # 08 Y:2023 08 2023 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $2,765 $0 n/a
MI0431 # 01 Y:2023 01 2023 UTILIZE A LESS EXPENSIVE COOLING METHOD $11,840 $55,500 n/a
UU0238 # 04 Y:2024 04 2024 CLEAN CONDENSER TUBES $3,894 $3,890 n/a