Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

62

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0253 # 04 Y:1995 04 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,365 $7,000 n/a
AR0075 # 08 Y:1995 08 1995 UTILIZE A LESS EXPENSIVE COOLING METHOD $2,520 $2,092 Implemented
OK0478 # 01 Y:1995 01 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $63,653 $25,000 Implemented
AS0164 # 01 Y:1995 01 1995 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,560 $4,976 Not Implemented
GT0568 # 03 Y:1995 03 1995 UTILIZE A LESS EXPENSIVE COOLING METHOD $2,630 $4,400 Not Implemented
MA0349 # 02 Y:1995 02 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $25,737 $27,186 Not Implemented
CO0347 # 06 Y:1995 06 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,890 $2,880 Implemented
NC0075 # 04 Y:1995 04 1995 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $5,067 $8,000 Implemented
GT0566 # 04 Y:1995 04 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $10,700 $0 Not Implemented
WI0252 # 05 Y:1995 05 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,698 $5,500 Not Implemented
UF0132 # 06 Y:1995 06 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $7,950 $15,000 Not Implemented
AS0162 # 05 Y:1995 05 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $4,099 $13,500 Not Implemented
WI0251 # 08 Y:1995 08 1995 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $2,740 $6,000 Implemented
AS0159 # 07 Y:1995 07 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $11,926 $31,350 Not Implemented
AS0159 # 06 Y:1995 06 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,366 $20,000 Not Implemented
IA0125 # 01 Y:1995 01 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $38,625 $95,200 Not Implemented
MS0036 # 04 Y:1995 04 1995 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $3,275 $800 Not Implemented
WI0246 # 07 Y:1995 07 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,406 $10,000 Not Implemented
UD0467 # 03 Y:1995 03 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $23,135 $150,000 Not Implemented
NC0061 # 06 Y:1995 06 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $64,115 $12,675 Not Implemented
MA0343 # 02 Y:1995 02 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,446 $9,000 Not Implemented
TN0552 # 03 Y:1995 03 1995 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $2,137 $0 Implemented
IA0115 # 02 Y:1995 02 1995 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,223 $8,195 Not Implemented
IA0114 # 12 Y:1995 12 1995 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $1,440 $5,725 Implemented
NC0058 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,940 $10,000 Not Implemented