Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
150
matching recommendationsARC | 2.3 | Electrical Power |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0958 # 13 Y:2016 | 13 | 2016 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $309,693 | $1,927,657 | Not Implemented |
OK0958 # 12 Y:2016 | 12 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,996 | $0 | Implemented |
WM0099 # 02 Y:2016 | 02 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,528 | $0 | Not Implemented |
OK0951 # 10 Y:2016 | 10 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $13,152 | $0 | Not Implemented |
SF0495 # 01 Y:2016 | 01 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,207 | $661 | Implemented |
SF0495 # 06 Y:2016 | 06 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,109 | $0 | Not Implemented |
BD0493 # 05 Y:2016 | 05 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,280 | $50 | n/a |
BD0492 # 10 Y:2016 | 10 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $285 | $200 | n/a |
WM0098 # 07 Y:2016 | 07 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,178 | $0 | Not Implemented |
AM0720 # 04 Y:2016 | 04 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,240 | $0 | Implemented |
BS0092 # 01 Y:2016 | 01 | 2016 | USE EXISTING DAM TO GENERATE ELECTRICITY | $84,096 | $646,400 | Not Implemented |
IP0075 # 03 Y:2016 | 03 | 2016 | OPTIMIZE PLANT POWER FACTOR | $144,133 | $37,215 | Not Implemented |
SF0494 # 01 Y:2016 | 01 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,238 | $0 | Implemented |
MA0768 # 05 Y:2016 | 05 | 2016 | OPTIMIZE PLANT POWER FACTOR | $515 | $3,480 | Not Implemented |
AM0718 # 02 Y:2016 | 02 | 2016 | OPTIMIZE PLANT POWER FACTOR | $53,431 | $280,072 | Not Implemented |
AM0718 # 03 Y:2016 | 03 | 2016 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $65,900 | $400,000 | Not Implemented |
OK0955 # 01 Y:2016 | 01 | 2016 | OPTIMIZE PLANT POWER FACTOR | $6,635 | $15,400 | Not Implemented |
MA0765 # 02 Y:2016 | 02 | 2016 | OPTIMIZE PLANT POWER FACTOR | $15,004 | $12,000 | Implemented |
BS0089 # 07 Y:2016 | 07 | 2016 | OPTIMIZE PLANT POWER FACTOR | $15,910 | $115,903 | Not Implemented |
MA0763 # 02 Y:2016 | 02 | 2016 | USE EXISTING DAM TO GENERATE ELECTRICITY | $14,909 | $68,625 | Not Implemented |
TT0181 # 10 Y:2016 | 10 | 2016 | OPTIMIZE PLANT POWER FACTOR | $3,012 | $8,000 | Implemented |
WM0095 # 05 Y:2016 | 05 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,197 | $0 | Not Implemented |
WM0095 # 01 Y:2016 | 01 | 2016 | STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS | $286,874 | $438,150 | Not Implemented |
UD0958 # 02 Y:2016 | 02 | 2016 | OPTIMIZE PLANT POWER FACTOR | $15,347 | $8,500 | Not Implemented |
NC0576 # 03 Y:2016 | 03 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $198,172 | $1,100,000 | Not Implemented |