Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
19
matching recommendationsARC | 2.5 | Industrial Design |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0773 # 11 Y:2003 | 11 | 2003 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $6,590 | $30,000 | Not Implemented |
TA0065 # 01 Y:2003 | 01 | 2003 | REDESIGN PROCESS | $75,086 | $0 | Implemented |
IC0069 # 06 Y:2003 | 06 | 2003 | REDESIGN PROCESS | $579 | $1,984 | Not Implemented |
SD0328 # 08 Y:2003 | 08 | 2003 | REDESIGN PROCESS | $55,557 | $24,000 | Not Implemented |
UD0675 # 08 Y:2003 | 08 | 2003 | REDUCE FLUID FLOW RATES | $2,011 | $1,200 | Not Implemented |
SU0164 # 07 Y:2003 | 07 | 2003 | REDESIGN PROCESS | $6,861 | $270 | Implemented |
MI0061 # 07 Y:2003 | 07 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $27,760 | $2,808 | Not Implemented |
IC0063 # 06 Y:2003 | 06 | 2003 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $36,807 | $250,000 | Not Implemented |
IC0063 # 07 Y:2003 | 07 | 2003 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $7,351 | $24,365 | Not Implemented |
OK0666 # 01 Y:2003 | 01 | 2003 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $15,468 | $30,000 | Not Implemented |
IA0317 # 07 Y:2003 | 07 | 2003 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $8,984 | $75,000 | Implemented |
BD0233 # 01 Y:2003 | 01 | 2003 | REDUCE FLUID FLOW RATES | $155,476 | $0 | Not Implemented |
LE0156 # 01 Y:2003 | 01 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $1,112 | $870 | Implemented |
GT0752 # 08 Y:2003 | 08 | 2003 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $1,773,429 | $6,000,000 | n/a |
IC0055 # 06 Y:2003 | 06 | 2003 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $9,243 | $61,200 | Not Implemented |
SD0314 # 04 Y:2003 | 04 | 2003 | REDESIGN PROCESS | $28,616 | $11,700 | Not Implemented |
NC0252 # 05 Y:2003 | 05 | 2003 | REDESIGN PROCESS | $4,814 | $780 | Implemented |
OR0427 # 03 Y:2003 | 03 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $15,700 | $55,400 | Not Implemented |
OR0426 # 05 Y:2003 | 05 | 2003 | SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE | $9,530 | $73,800 | Not Implemented |