Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,708
matching recommendationsARC | 2.72 | SPACE CONDITIONING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0026 # 02 Y:2008 | 02 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,500 | $0 | Implemented |
DL0026 # 07 Y:2008 | 07 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $23,000 | $40,000 | Implemented |
GT0855 # 06 Y:2008 | 06 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $834 | $2,100 | Not Implemented |
SF0364 # 16 Y:2008 | 16 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,581 | $35,138 | Implemented |
SF0364 # 02 Y:2008 | 02 | 2008 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $4,812 | $1,046 | Implemented |
SF0364 # 09 Y:2008 | 09 | 2008 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $9,060 | $11,740 | Implemented |
UM0343 # 04 Y:2008 | 04 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $3,750 | $0 | Implemented |
UF0415 # 09 Y:2008 | 09 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $49,178 | $49,400 | Not Implemented |
LE0279 # 05 Y:2008 | 05 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,306 | $15,525 | Not Implemented |
LL0303 # 06 Y:2008 | 06 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $232 | $33 | Not Implemented |
LE0278 # 03 Y:2008 | 03 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $17,728 | $16,000 | Not Implemented |
LE0278 # 04 Y:2008 | 04 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $12,408 | $9,600 | Not Implemented |
LE0278 # 13 Y:2008 | 13 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,785 | $450 | Implemented |
UM0342 # 01 Y:2008 | 01 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,661 | $7,350 | Not Implemented |
BD0348 # 06 Y:2008 | 06 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $7,689 | $5,001 | Not Implemented |
BD0350 # 10 Y:2008 | 10 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $52,447 | $9,000 | Implemented |
LL0302 # 01 Y:2008 | 01 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $14,663 | $30 | Implemented |
LL0302 # 03 Y:2008 | 03 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,364 | $450 | Implemented |
LL0301 # 05 Y:2008 | 05 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,436 | $1,650 | Not Implemented |
DL0021 # 05 Y:2008 | 05 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,560 | $0 | Not Implemented |
IA0434 # 11 Y:2008 | 11 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $12,653 | $7,425 | Implemented |
IA0434 # 09 Y:2008 | 09 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,060 | $15,120 | Implemented |
IA0433 # 07 Y:2008 | 07 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,364 | $4,000 | Implemented |
IA0433 # 08 Y:2008 | 08 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $587 | $142 | Implemented |
LE0276 # 01 Y:2008 | 01 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $144,000 | $92,000 | Implemented |