Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,708

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0061 # 03 Y:2003 03 2003 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $2,000 $300 Implemented
WV0271 # 03 Y:2003 03 2003 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $36,152 $180,000 Not Implemented
MA0538 # 06 Y:2003 06 2003 USE RADIANT HEATER FOR SPOT HEATING $10,594 $44,750 Not Implemented
UF0328 # 01 Y:2003 01 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $10,395 $0 Implemented
UD0674 # 01 Y:2003 01 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $18,633 $45,760 Not Implemented
UD0674 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $753 $1,048 Not Implemented
WI0448 # 05 Y:2003 05 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,558 $1,200 Not Implemented
IA0319 # 07 Y:2003 07 2003 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $5,530 $2,910 Not Implemented
AS0359 # 02 Y:2003 02 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $73,763 $118,320 Not Implemented
SF0263 # 05 Y:2003 05 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,730 $20,475 Not Implemented
UM0237 # 05 Y:2003 05 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,146 $2,100 Not Implemented
AS0358 # 05 Y:2003 05 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,266 $4,000 Implemented
MS0229 # 06 Y:2003 06 2003 INSTALL TIMERS AND/OR THERMOSTATS $434 $472 Not Implemented
UM0236 # 01 Y:2003 01 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $9,379 $700 Not Implemented
AS0357 # 01 Y:2003 01 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,658 $5,500 Not Implemented
OK0665 # 04 Y:2003 04 2003 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,748 $3,480 Implemented
BD0237 # 01 Y:2003 01 2003 USE RADIANT HEATER FOR SPOT HEATING $32,297 $56,000 Not Implemented
AS0356 # 10 Y:2003 10 2003 AIR CONDITION ONLY SPACE NECESSARY $957 $4,260 Not Implemented
AS0356 # 08 Y:2003 08 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $39,566 $55,100 n/a
AS0355 # 05 Y:2003 05 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $573 $1,500 Not Implemented
AS0355 # 02 Y:2003 02 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $395 $0 Not Implemented
SD0326 # 08 Y:2003 08 2003 INSTALL TIMERS AND/OR THERMOSTATS $2,034 $500 Not Implemented
MA0534 # 06 Y:2003 06 2003 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $10,591 $8,425 Not Implemented
MS0228 # 05 Y:2003 05 2003 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $323 $0 Implemented
BD0236 # 01 Y:2003 01 2003 USE RADIANT HEATER FOR SPOT HEATING $20,989 $23,000 Not Implemented