Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
135
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD1008 # 10 Y:2019 | 10 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,896 | $500 | Implemented |
MI0365 # 07 Y:2019 | 07 | 2019 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $10,416 | $10,416 | Not Implemented |
MI0365 # 10 Y:2019 | 10 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,083 | $960 | Not Implemented |
UK1916 # 10 Y:2019 | 10 | 2019 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $139,706 | $225,000 | n/a |
IC0227 # 05 Y:2019 | 05 | 2019 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,871 | $28,000 | Not Implemented |
UK1915 # 02 Y:2019 | 02 | 2019 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $7,951 | $17,032 | n/a |
NC0643 # 02 Y:2019 | 02 | 2019 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $9,495 | $1,000 | Implemented |
UU0158 # 02 Y:2019 | 02 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,811 | $160 | Not Implemented |
BS0132 # 03 Y:2019 | 03 | 2019 | OPERATE BOILERS ON HIGH FIRE SETTING | $51,880 | $0 | Not Implemented |
OK1020 # 05 Y:2019 | 05 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $33,536 | $500 | Not Implemented |
LE0485 # 05 Y:2019 | 05 | 2019 | REPLACE BOILER | $162,332 | $344,000 | Not Implemented |
WM0145 # 03 Y:2019 | 03 | 2019 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $7,173 | $2,200 | Not Implemented |
MI0362 # 10 Y:2019 | 10 | 2019 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $288 | $187 | Implemented |
GT0936 # 07 Y:2019 | 07 | 2019 | BURN A LESS EXPENSIVE GRADE OF FUEL | $9,120 | $9,016 | Implemented |
WM0145 # 01 Y:2019 | 01 | 2019 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $29,234 | $3,500 | Not Implemented |
IC0224 # 04 Y:2019 | 04 | 2019 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,174 | $5,784 | Implemented |
IC0224 # 05 Y:2019 | 05 | 2019 | REPLACE BOILER | $11,695 | $66,600 | Implemented |
UF0541 # 06 Y:2019 | 06 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,871 | $1,550 | Implemented |
UF0541 # 05 Y:2019 | 05 | 2019 | INSTALL TURBULATORS | $5,920 | $7,500 | Not Implemented |
UF0540 # 02 Y:2019 | 02 | 2019 | BURN A LESS EXPENSIVE GRADE OF FUEL | $99,716 | $392,375 | Implemented |
TT0230 # 02 Y:2019 | 02 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,000 | $6,000 | Not Implemented |
TT0230 # 04 Y:2019 | 04 | 2019 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,630 | $30,000 | Not Implemented |
LE0484 # 07 Y:2019 | 07 | 2019 | BURN A LESS EXPENSIVE GRADE OF FUEL | $87,917 | $290,000 | Implemented |
MA0809 # 02 Y:2019 | 02 | 2019 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,745 | $11,800 | Not Implemented |
WV0587 # 04 Y:2019 | 04 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,887 | $4,500 | Implemented |