IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,470

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0102 # 01 Y:1990 01 1990 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,402 $2,500 Implemented
GT0422 # 02 Y:1990 02 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,600 $1,000 Implemented
GT0424 # 02 Y:1990 02 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,180 $150 Implemented
AM0102 # 03 Y:1990 03 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,400 $540 Implemented
GT0423 # 08 Y:1990 08 1990 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,250 $7,000 Implemented
OK0329 # 01 Y:1990 01 1990 INSTALL TURBULATORS $536 $1,550 Not Implemented
WI0102 # 04 Y:1990 04 1990 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $56 $66 Implemented
OK0328 # 01 Y:1990 01 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $38,923 $18,700 Not Implemented
RU0104 # 07 Y:1990 07 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $20,685 $63,000 Implemented
WI0101 # 07 Y:1990 07 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,897 $4,000 Not Implemented
MA0197 # 06 Y:1990 06 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,680 $927 Implemented
MA0198 # 04 Y:1990 04 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $58,450 $102,564 Implemented
GT0414 # 05 Y:1990 05 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $35,514 $27,680 Not Implemented
MA0192 # 07 Y:1990 07 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $162 $436 Implemented
MA0193 # 02 Y:1990 02 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $13,252 $12,000 Not Implemented
MO0014 # 06 Y:1990 06 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $472 $650 Implemented
MO0014 # 07 Y:1990 07 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $351 $450 Implemented
OK0321 # 01 Y:1990 01 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $39,907 $25,000 Implemented
CO0195 # 01 Y:1990 01 1990 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $6,200 $5,400 Not Implemented
RU0099 # 07 Y:1990 07 1990 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $3,953 $45,000 Not Implemented
KU0322 # 01 Y:1990 01 1990 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,059 $10,000 Not Implemented
CO0194 # 02 Y:1990 02 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,039 $2,000 Implemented
CO0196 # 04 Y:1990 04 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $420 $1,000 Not Implemented
GT0416 # 02 Y:1990 02 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $21,055 $400 Implemented
GT0417 # 06 Y:1990 06 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,970 $450 Implemented