Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,326

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0096 # 04 Y:2012 04 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $15,197 $16,000 Not Implemented
WV0454 # 03 Y:2012 03 2012 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $4,992 $13,611 Not Implemented
WV0453 # 03 Y:2012 03 2012 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $4,494 $12,500 Not Implemented
UK1211 # 03 Y:2012 03 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,299 $7,500 Not Implemented
MZ0095 # 04 Y:2012 04 2012 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $7,949 $1,660 Not Implemented
WV0453 # 11 Y:2012 11 2012 DIRECT WARMEST AIR TO COMBUSTION INTAKE $251 $800 Not Implemented
LE0342 # 06 Y:2012 06 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,433 $40,000 Implemented
LE0342 # 09 Y:2012 09 2012 REPLACE BOILER $225,837 $230,000 Implemented
UK1210 # 08 Y:2012 08 2012 KEEP BOILER TUBES CLEAN $6,493 $2,410 Not Implemented
UK1210 # 09 Y:2012 09 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,708 $100 Not Implemented
IA0484 # 01 Y:2012 01 2012 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,225 $401 Not Implemented
MZ0092 # 03 Y:2012 03 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,594 $1,000 Implemented
WV0452 # 07 Y:2012 07 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,507 $2,500 Implemented
WV0451 # 13 Y:2012 13 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,600 $2,500 Implemented
MA0697 # 03 Y:2012 03 2012 IMPROVE COMBUSTION CONTROL CAPABILITY $23,122 $100,000 Not Implemented
WV0451 # 04 Y:2012 04 2012 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $4,597 $27,000 Not Implemented
UA3019 # 10 Y:2012 10 2012 IMPROVE COMBUSTION CONTROL CAPABILITY $28,009 $90,000 Not Implemented
UA3019 # 12 Y:2012 12 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,737 $800 Not Implemented
UD0859 # 08 Y:2012 08 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,768 $2,000 Implemented
UD0859 # 10 Y:2012 10 2012 REDUCE EXCESSIVE BOILER BLOWDOWN $4,657 $5,000 Not Implemented
NC0456 # 03 Y:2012 03 2012 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $28,806 $60,000 Not Implemented
MA0695 # 01 Y:2012 01 2012 BURN A LESS EXPENSIVE GRADE OF FUEL $24,095 $20,000 Not Implemented
SD0451 # 01 Y:2012 01 2012 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $35,395 $14,332 Implemented
SD0452 # 01 Y:2012 01 2012 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $48,619 $2,000 Implemented
UMS010 # 02 Y:2012 02 2012 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $16,000 $10,000 Not Implemented