Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

189

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0194 # 03 Y:2001 03 2001 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $26,678 $32,890 n/a
MS0195 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,494 $1,000 Implemented
MS0194 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $75,156 $10,000 n/a
OK0628 # 04 Y:2001 04 2001 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,448 $1,500 Implemented
MA0503 # 01 Y:2001 01 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $46,957 $57,500 n/a
MA0503 # 03 Y:2001 03 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,833 $13,000 n/a
OK0628 # 10 Y:2001 10 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $42,112 $100,000 Not Implemented
OK0628 # 07 Y:2001 07 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $20,767 $5,653 Not Implemented
MA0503 # 05 Y:2001 05 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,038 $10,000 Not Implemented
MA0503 # 06 Y:2001 06 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $911 $6,000 Not Implemented
IC0024 # 03 Y:2001 03 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $7,403 $2,000 Implemented
IC0024 # 04 Y:2001 04 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,943 $4,000 Implemented
UU0018 # 04 Y:2001 04 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,006 $1,000 Implemented
IC0024 # 01 Y:2001 01 2001 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $27,240 $6,825 Not Implemented
OK0615 # 06 Y:2001 06 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,998 $6,000 Not Implemented
OK0615 # 10 Y:2001 10 2001 REPLACE BOILER $7,761 $22,000 Not Implemented
AS0314 # 05 Y:2001 05 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $283 $766 Not Implemented
WI0408 # 07 Y:2001 07 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,941 $11,250 n/a
GT0722 # 01 Y:2001 01 2001 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $16,455 $5,110 Implemented
MA0502 # 05 Y:2001 05 2001 REPLACE BOILER $1,908 $1,908 Not Implemented
GT0721 # 03 Y:2001 03 2001 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $38,845 $80,000 n/a
IA0284 # 04 Y:2001 04 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $4,016 $800 Implemented
MS0192 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,993 $1,000 Implemented
MS0191 # 01 Y:2001 01 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $35,695 $1,000 Implemented
MS0191 # 02 Y:2001 02 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,525 $1,000 Implemented