Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

159

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0373 # 02 Y:2011 02 2011 BURN A LESS EXPENSIVE GRADE OF FUEL $32,874 $100,490 Not Implemented
BD0394 # 01 Y:2011 01 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $58,796 $139,000 Not Implemented
BD0394 # 02 Y:2011 02 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $35,291 $9,000 Not Implemented
SD0437 # 04 Y:2011 04 2011 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $2,194 $610 Not Implemented
NC0426 # 07 Y:2011 07 2011 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $5,569 $21,550 Not Implemented
SD0437 # 02 Y:2011 02 2011 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $58,730 $2,850 Implemented
SF0399 # 10 Y:2011 10 2011 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $6,800 $37,014 Not Implemented
UM0391 # 01 Y:2011 01 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $38,198 $7,100 Not Implemented
UM0391 # 02 Y:2011 02 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $3,190 $2,000 Not Implemented
UM0391 # 04 Y:2011 04 2011 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $4,244 $1,000 Implemented
UD0839 # 10 Y:2011 10 2011 OPERATE BOILERS ON HIGH FIRE SETTING $11,810 $23,620 Implemented
UD0839 # 08 Y:2011 08 2011 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $80,401 $90,000 Not Implemented
UD0839 # 09 Y:2011 09 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,418 $3,000 Implemented
IC0184 # 01 Y:2011 01 2011 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $265,693 $277,838 Not Implemented
LE0319 # 04 Y:2011 04 2011 OPERATE BOILERS ON HIGH FIRE SETTING $16,771 $0 Implemented
WV0428 # 06 Y:2011 06 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,763 $1,000 Implemented
UF0444 # 12 Y:2011 12 2011 INSTALL TURBULATORS $16,282 $7,500 Not Implemented
DL0073 # 02 Y:2011 02 2011 REPLACE BOILER $420,000 $408,000 Not Implemented
UM0387 # 01 Y:2011 01 2011 OPERATE BOILERS ON HIGH FIRE SETTING $48,827 $157,500 Not Implemented
BD0393 # 02 Y:2011 02 2011 DIRECT WARMEST AIR TO COMBUSTION INTAKE $8,510 $10,000 Not Implemented
TT0066 # 05 Y:2011 05 2011 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,200 $600 Not Implemented
BD0393 # 01 Y:2011 01 2011 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $54,406 $4,000 Not Implemented
UA0061 # 03 Y:2011 03 2011 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $27,256 $85,000 Not Implemented
WV0427 # 05 Y:2011 05 2011 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,786 $1,000 Implemented
IC0182 # 09 Y:2011 09 2011 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $2,442 $311 Not Implemented