Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

148

matching recommendations
Reset
ARC 2.12 BOILERS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0285 # 03 Y:1993 03 1993 REPLACE BOILER $26,214 $0 Implemented
WI0192 # 01 Y:1993 01 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,147 $500 Implemented
KU0411 # 06 Y:1993 06 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $976 $1,200 Implemented
GT0504 # 01 Y:1993 01 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $12,225 $900 Implemented
SF0013 # 06 Y:1993 06 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,149 $2,500 Implemented
ME0108 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,170 $250 Implemented
NC0015 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,985 $600 Not Implemented
AS0101 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $201 $500 Not Implemented
CO0287 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,360 $2,500 Not Implemented
IA0068 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,707 $1,000 Implemented
IA0068 # 03 Y:1993 03 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,173 $1,364 Not Implemented
GT0501 # 01 Y:1993 01 1993 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $5,620 $10,000 Implemented
GT0501 # 02 Y:1993 02 1993 REDUCE EXCESSIVE BOILER BLOWDOWN $1,760 $0 Not Implemented
WI0190 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,245 $500 Implemented
WV0015 # 06 Y:1993 06 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $8,836 $1,961 Implemented
ND0155 # 05 Y:1993 05 1993 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $3,842 $40 Implemented
OR0184 # 01 Y:1993 01 1993 KEEP BOILER TUBES CLEAN $3,632 $500 Implemented
WV0014 # 06 Y:1993 06 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $90,331 $5,000 Implemented
ND0170 # 08 Y:1993 08 1993 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $307 $4,550 Not Implemented
AS0097 # 02 Y:1993 02 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,546 $2,000 Not Implemented
TN0504 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,202 $1,500 Implemented
NC0007 # 08 Y:1993 08 1993 INSTALL TURBULATORS $8,700 $1,500 Implemented
GT0503 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $780 $450 Implemented
KU0407 # 03 Y:1993 03 1993 DIRECT WARMEST AIR TO COMBUSTION INTAKE $986 $2,400 Not Implemented
GT0503 # 06 Y:1993 06 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,340 $0 Not Implemented