Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,767

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0266 # 01 Y:2004 01 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $11,825 $4,500 Implemented
SU0193 # 06 Y:2004 06 2004 RECOVER WASTE HEAT FROM EQUIPMENT $489 $304 Implemented
LL0204 # 03 Y:2004 03 2004 REPAIR AND ELIMINATE STEAM LEAKS $6,025 $3,880 Implemented
BD0271 # 04 Y:2004 04 2004 REPLACE AIR CURTAIN DOORS WITH SOLID DOORS $15,124 $6,800 Implemented
WV0307 # 03 Y:2004 03 2004 ISOLATE HOT OR COLD EQUIPMENT $3,113 $755 Implemented
WV0307 # 12 Y:2004 12 2004 USE OPTIMUM THICKNESS INSULATION $278 $380 Implemented
WV0307 # 13 Y:2004 13 2004 INSULATE BARE EQUIPMENT $262 $260 Implemented
WV0306 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $17,374 $5,922 Implemented
OR0467 # 03 Y:2004 03 2004 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $2,000 $31,500 Implemented
OK0694 # 05 Y:2004 05 2004 INSULATE BARE EQUIPMENT $2,247 $2,094 Implemented
AM0472 # 01 Y:2004 01 2004 REPAIR OR REPLACE STEAM TRAPS $6,580 $590 Implemented
AM0472 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $6,640 $720 Implemented
WV0305 # 02 Y:2004 02 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,442 $1,774 Implemented
WV0305 # 07 Y:2004 07 2004 REPAIR OR REPLACE STEAM TRAPS $2,040 $1,870 Implemented
WV0305 # 11 Y:2004 11 2004 INSULATE BARE EQUIPMENT $1,275 $591 Implemented
OR0465 # 02 Y:2004 02 2004 INCREASE AMOUNT OF CONDENSATE RETURNED $46,600 $14,000 Implemented
LE0197 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $52,852 $10,000 Implemented
WV0304 # 04 Y:2004 04 2004 INSULATE BARE EQUIPMENT $5,483 $4,491 Implemented
WV0304 # 10 Y:2004 10 2004 INSULATE BARE EQUIPMENT $509 $44 Implemented
UU0068 # 01 Y:2004 01 2004 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $21,193 $325 Implemented
BD0269 # 02 Y:2004 02 2004 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $3,568 $3,200 Implemented
AM0471 # 01 Y:2004 01 2004 REPAIR OR REPLACE STEAM TRAPS $7,600 $930 Implemented
AM0471 # 02 Y:2004 02 2004 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $6,640 $4,600 Implemented
AM0471 # 06 Y:2004 06 2004 INSULATE BARE EQUIPMENT $1,110 $170 Implemented
UD0705 # 10 Y:2004 10 2004 COVER OPEN TANKS $710 $0 Implemented