Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
219
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0769 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,200 | $130,000 | Implemented |
UF0406 # 05 Y:2007 | 05 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $17,857 | $619 | Implemented |
UM0329 # 02 Y:2007 | 02 | 2007 | COVER OPEN TANKS | $115,389 | $140,000 | Implemented |
AM0534 # 04 Y:2007 | 04 | 2007 | COVER OPEN TANKS | $2,500 | $0 | Implemented |
DL0008 # 08 Y:2007 | 08 | 2007 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $3,800 | $900 | Implemented |
DL0008 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $40,014 | $14,000 | Implemented |
SD0398 # 03 Y:2007 | 03 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $2,091 | $150 | Implemented |
TT0012 # 01 Y:2007 | 01 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $331 | $600 | Implemented |
TT0012 # 03 Y:2007 | 03 | 2007 | Leaks and Insulation | $9,860 | $1,491 | Implemented |
NC0369 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,750 | $13,500 | Implemented |
GT0842 # 07 Y:2007 | 07 | 2007 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $63,520 | $7,000 | Implemented |
GT0842 # 01 Y:2007 | 01 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,980 | $1,603 | Implemented |
SU0257 # 06 Y:2007 | 06 | 2007 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $323,145 | $79,171 | Implemented |
DL0007 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,672 | $75 | Implemented |
SU0257 # 08 Y:2007 | 08 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $561 | $250 | Implemented |
SU0256 # 03 Y:2007 | 03 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $16,749 | $875 | Implemented |
SU0256 # 04 Y:2007 | 04 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $11,056 | $11,106 | Implemented |
UM0328 # 10 Y:2007 | 10 | 2007 | INSULATE BARE EQUIPMENT | $1,625 | $1,238 | Implemented |
DL0006 # 01 Y:2007 | 01 | 2007 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $3,642 | $0 | Implemented |
NC0366 # 05 Y:2007 | 05 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,430 | $12,000 | Implemented |
MA0622 # 02 Y:2007 | 02 | 2007 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $653,801 | $423,075 | Implemented |
NC0366 # 04 Y:2007 | 04 | 2007 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $71,297 | $280,000 | Implemented |
MA0622 # 07 Y:2007 | 07 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $21,165 | $10,000 | Implemented |
UM0327 # 08 Y:2007 | 08 | 2007 | COVER OPEN TANKS | $561 | $275 | Implemented |
UM0326 # 07 Y:2007 | 07 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,476 | $2,200 | Implemented |