Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,019
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0867 # 07 Y:2013 | 07 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $747 | $1,909 | Not Implemented |
OK0867 # 11 Y:2013 | 11 | 2013 | INSULATE BARE EQUIPMENT | $15 | $44 | Implemented |
OR0614 # 01 Y:2013 | 01 | 2013 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $31,637 | $42,000 | Not Implemented |
OR0614 # 02 Y:2013 | 02 | 2013 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,101 | $10,000 | Implemented |
OR0614 # 04 Y:2013 | 04 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,554 | $1,828 | Not Implemented |
OR0614 # 05 Y:2013 | 05 | 2013 | INSULATE BARE EQUIPMENT | $667 | $446 | Not Implemented |
BS0019 # 07 Y:2013 | 07 | 2013 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $23 | $25 | Implemented |
BS0019 # 10 Y:2013 | 10 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $142 | $551 | Implemented |
IA0508 # 02 Y:2013 | 02 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $14,349 | $3,750 | Implemented |
IA0508 # 09 Y:2013 | 09 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,758 | $976 | Implemented |
MI0247 # 02 Y:2013 | 02 | 2013 | INSULATE BARE EQUIPMENT | $118,483 | $20,790 | Not Implemented |
OR0613 # 05 Y:2013 | 05 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,364 | $17,632 | Not Implemented |
BS0021 # 01 Y:2013 | 01 | 2013 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $209,585 | $54,045 | Not Implemented |
BS0021 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $258 | $1,952 | Not Implemented |
BS0021 # 05 Y:2013 | 05 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $264,262 | $84,783 | Not Implemented |
SU0350 # 06 Y:2013 | 06 | 2013 | INSULATE FEEDWATER TANK | $579 | $190 | Implemented |
SU0350 # 07 Y:2013 | 07 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $579 | $340 | Implemented |
WM0030 # 01 Y:2013 | 01 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,439 | $1,853 | Not Implemented |
SF0439 # 02 Y:2013 | 02 | 2013 | INSULATE BARE EQUIPMENT | $3,654 | $436 | Implemented |
SF0439 # 15 Y:2013 | 15 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,319 | $118,398 | Not Implemented |
IP0018 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $5,669 | $2,019 | Not Implemented |
IA0507 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $9,686 | $7,803 | Implemented |
CO0676 # 03 Y:2013 | 03 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $730 | $900 | Implemented |
WV0474 # 05 Y:2013 | 05 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $2,920 | $72 | Implemented |
UM0433 # 04 Y:2013 | 04 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $37,193 | $1,000 | Implemented |