Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,025

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0358 # 05 Y:2009 05 2009 RECOVER WASTE HEAT FROM EQUIPMENT $24,734 $501 Not Implemented
UA0037 # 09 Y:2009 09 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,938 $6,000 Implemented
UA0037 # 03 Y:2009 03 2009 REPAIR AND ELIMINATE STEAM LEAKS $60,900 $1,744 Implemented
UA0037 # 04 Y:2009 04 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $25,667 $3,523 Implemented
UA0037 # 08 Y:2009 08 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $58,174 $32,445 Implemented
IC0156 # 11 Y:2009 11 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $1,559 $2,887 Implemented
DL0038 # 04 Y:2009 04 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,056 $1,430 Not Implemented
UW0028 # 01 Y:2009 01 2009 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,467,516 $2,201,270 Not Implemented
UW0028 # 02 Y:2009 02 2009 PREHEAT COMBUSTION AIR WITH WASTE HEAT $323,442 $485,164 Not Implemented
SF0374 # 07 Y:2009 07 2009 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $17,939 $12,500 Implemented
SF0374 # 01 Y:2009 01 2009 REPAIR AND ELIMINATE STEAM LEAKS $45,410 $0 Implemented
UA0036 # 05 Y:2009 05 2009 RECOVER WASTE HEAT FROM EQUIPMENT $6,452 $10,320 Not Implemented
UD0797 # 01 Y:2009 01 2009 RECOVER WASTE HEAT FROM EQUIPMENT $141,216 $250,000 Not Implemented
UW0027 # 03 Y:2009 03 2009 INSULATE BARE EQUIPMENT $5,716 $871 Not Implemented
LL0310 # 01 Y:2009 01 2009 INSULATE BARE EQUIPMENT $11,141 $1,220 Implemented
LL0310 # 05 Y:2009 05 2009 INSULATE BARE EQUIPMENT $500 $441 Implemented
UD0797 # 02 Y:2009 02 2009 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $61,511 $5,000 Not Implemented
UD0797 # 05 Y:2009 05 2009 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $23,393 $75,000 Not Implemented
UD0797 # 07 Y:2009 07 2009 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,835 $75,000 Not Implemented
UW0027 # 02 Y:2009 02 2009 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $6,650 $37,000 Not Implemented
UF0420 # 05 Y:2009 05 2009 PREHEAT COMBUSTION AIR WITH WASTE HEAT $5,022 $10,000 Not Implemented
NC0389 # 02 Y:2009 02 2009 RECOVER WASTE HEAT FROM EQUIPMENT $3,172 $4,300 Not Implemented
OK0775 # 03 Y:2009 03 2009 RECOVER WASTE HEAT FROM EQUIPMENT $6,617 $5,534 Not Implemented
SU0281 # 13 Y:2009 13 2009 RECOVER WASTE HEAT FROM EQUIPMENT $1,072 $4,000 Implemented
SU0281 # 06 Y:2009 06 2009 REPAIR AND ELIMINATE STEAM LEAKS $3,172 $53 Implemented