Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0233 # 02 Y:2003 02 2003 PREHEAT COMBUSTION AIR WITH WASTE HEAT $67,762 $79,500 Not Implemented
AM0443 # 02 Y:2003 02 2003 INSULATE BARE EQUIPMENT $19,270 $2,100 n/a
OK0668 # 08 Y:2003 08 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $31,772 $9,500 Not Implemented
UD0678 # 07 Y:2003 07 2003 USE OPTIMUM TEMPERATURE $5,406 $500 Not Implemented
MI0065 # 03 Y:2003 03 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $2,876 $4,556 n/a
OK0668 # 09 Y:2003 09 2003 INSULATE BARE EQUIPMENT $1,369 $1,455 Implemented
IC0065 # 02 Y:2003 02 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $243,209 $1,400,000 Implemented
WV0276 # 07 Y:2003 07 2003 REPAIR OR REPLACE STEAM TRAPS $2,328 $480 Implemented
WV0276 # 05 Y:2003 05 2003 USE OPTIMUM THICKNESS INSULATION $8,395 $2,640 Implemented
WV0276 # 01 Y:2003 01 2003 INSTALL WASTE HEAT BOILER TO PRODUCE STEAM $41,760 $60,000 Implemented
IA0325 # 03 Y:2003 03 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $53,817 $18,000 Implemented
WV0275 # 03 Y:2003 03 2003 RECOVER WASTE HEAT FROM EQUIPMENT $16,752 $1,110 Not Implemented
GT0748 # 07 Y:2003 07 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $22,400 $22,800 n/a
GT0765 # 05 Y:2003 05 2003 USE MINIMUM STEAM OPERATING PRESSURE $750 $0 Not Implemented
GT0748 # 06 Y:2003 06 2003 USE OPTIMUM TEMPERATURE $76,382 $16,640 n/a
GT0765 # 08 Y:2003 08 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $420 $460 Not Implemented
UU0051 # 06 Y:2003 06 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,510 $5,980 Not Implemented
GT0765 # 09 Y:2003 09 2003 REPAIR AND ELIMINATE STEAM LEAKS $1,155 $300 Not Implemented
UM0239 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $18,295 $24,675 Not Implemented
UM0239 # 06 Y:2003 06 2003 COVER OPEN TANKS $7,400 $3,290 Not Implemented
LE0167 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $5,770 $985 Not Implemented
WV0274 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $22,034 $1,640 Not Implemented
WV0274 # 04 Y:2003 04 2003 INSULATE BARE EQUIPMENT $3,173 $252 Implemented
UD0677 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $1,019 $252 Not Implemented
UD0677 # 11 Y:2003 11 2003 INSULATE BARE EQUIPMENT $737 $200 Implemented