Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UU0048 # 06 Y:2003 06 2003 REPAIR OR REPLACE STEAM TRAPS $16,294 $5,000 Not Implemented
NC0262 # 01 Y:2003 01 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $10,471 $10,000 Not Implemented
TA0061 # 11 Y:2003 11 2003 INSULATE BARE EQUIPMENT $140 $255 Not Implemented
TA0061 # 04 Y:2003 04 2003 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $1,870 $435 Implemented
GT0764 # 01 Y:2003 01 2003 COVER OPEN TANKS $17,200 $0 Implemented
GT0764 # 03 Y:2003 03 2003 COVER OPEN TANKS $7,550 $2,505 Not Implemented
OK0667 # 04 Y:2003 04 2003 RECOVER WASTE HEAT FROM EQUIPMENT $4,471 $1,855 Not Implemented
OK0667 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $931 $185 Not Implemented
OK0667 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $551 $2,519 Not Implemented
NC0263 # 05 Y:2003 05 2003 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $8,768 $10,000 Not Implemented
NC0263 # 06 Y:2003 06 2003 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $46,271 $135,400 Not Implemented
NC0260 # 02 Y:2003 02 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $19,437 $8,000 Not Implemented
NC0260 # 03 Y:2003 03 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $16,074 $9,000 Not Implemented
WV0271 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $76,401 $2,253 Implemented
MS0230 # 05 Y:2003 05 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $724 $1,800 Not Implemented
MS0230 # 08 Y:2003 08 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $233 $602 Not Implemented
MS0230 # 07 Y:2003 07 2003 REPAIR AND ELIMINATE STEAM LEAKS $238 $62 Implemented
WV0271 # 07 Y:2003 07 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,967 $1,741 Not Implemented
WV0271 # 06 Y:2003 06 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,697 $32 Not Implemented
MA0538 # 05 Y:2003 05 2003 COVER OPEN TANKS $12,160 $39,000 Not Implemented
UD0675 # 11 Y:2003 11 2003 RECOVER WASTE HEAT FROM EQUIPMENT $525 $1,750 Not Implemented
LE0165 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $8,970 $1,440 Implemented
LE0165 # 06 Y:2003 06 2003 MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS $3,608 $500 Not Implemented
UM0238 # 06 Y:2003 06 2003 RECOVER WASTE HEAT FROM EQUIPMENT $3,280 $2,600 Not Implemented
MA0537 # 05 Y:2003 05 2003 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,043 $3,500 Not Implemented