Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IC0056 # 09 Y:2003 09 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $1,770 $2,052 Not Implemented
IC0056 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $2,293 $683 Not Implemented
IC0056 # 11 Y:2003 11 2003 INSULATE BARE EQUIPMENT $1,329 $400 Not Implemented
GT0750 # 05 Y:2003 05 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $1,058 $372 Implemented
GT0750 # 06 Y:2003 06 2003 INCREASE AMOUNT OF CONDENSATE RETURNED $17,688 $5,200 Not Implemented
GT0750 # 08 Y:2003 08 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,570 $27,000 Not Implemented
TA0050 # 02 Y:2003 02 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $47,100 $5,202 Implemented
NC0254 # 05 Y:2003 05 2003 COVER OPEN TANKS $14,740 $0 Not Implemented
NC0254 # 09 Y:2003 09 2003 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $88,312 $160,000 Not Implemented
UU0040 # 02 Y:2003 02 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $150 $0 Not Implemented
UU0040 # 06 Y:2003 06 2003 RECOVER WASTE HEAT FROM EQUIPMENT $57 $55 Not Implemented
OR0428 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $742 $1,320 Not Implemented
UD0666 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $3,082 $0 Not Implemented
SD0318 # 02 Y:2003 02 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,503 $25,000 Not Implemented
SU0159 # 01 Y:2003 01 2003 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $5,869 $18,122 Not Implemented
LL0154 # 01 Y:2003 01 2003 REPAIR AND ELIMINATE STEAM LEAKS $18,488,939 $413,700 n/a
LL0154 # 02 Y:2003 02 2003 INCREASE AMOUNT OF CONDENSATE RETURNED $11,340,034 $773,535 n/a
LL0154 # 04 Y:2003 04 2003 REDUCE EXCESS STEAM BLEEDING $504,716 $45,360 Not Implemented
LL0154 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $11,082 $2,865 Not Implemented
MA0531 # 06 Y:2003 06 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $445 $383 n/a
SF0232 # 02 Y:2002 02 2002 INCREASE AMOUNT OF CONDENSATE RETURNED $443 $325 Not Implemented
UD0665 # 02 Y:2003 02 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $74,995 $40,000 Not Implemented
UD0665 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $14,021 $1,545 Not Implemented
UD0665 # 04 Y:2003 04 2003 COVER OPEN TANKS $7,200 $12,000 Not Implemented
UD0665 # 10 Y:2003 10 2003 COVER OPEN TANKS $256 $400 Implemented