Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,009

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LS0322 # 01 Y:2022 01 2022 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $34,447 $250 Implemented
MA0830 # 03 Y:2022 03 2022 RECOVER WASTE HEAT FROM EQUIPMENT $15,862 $65,410 Not Implemented
MA0830 # 01 Y:2022 01 2022 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $118,337 $192,000 Not Implemented
MA0830 # 04 Y:2022 04 2022 MODERATE COOLING TOWER OUTLET TEMPERATURE $9,470 $2,500 Not Implemented
LE0517 # 05 Y:2022 05 2022 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $7,886 $28,000 Not Implemented
LE0517 # 03 Y:2022 03 2022 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $52,000 $100,000 Implemented
LS0122 # 05 Y:2022 05 2022 USE OPTIMUM THICKNESS INSULATION $2,779 $6,297 Implemented
SF0581 # 07 Y:2022 07 2022 REPAIR AND ELIMINATE STEAM LEAKS $2,960 $2,345 Not Implemented
SF0581 # 05 Y:2022 05 2022 INSULATE BARE EQUIPMENT $7,711 $3,227 Not Implemented
LS2208 # 01 Y:2022 01 2022 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $378 $10 Not Implemented
LS2208 # 06 Y:2022 06 2022 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $9,660 $2,800 Not Implemented
SF0580 # 03 Y:2021 03 2021 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $69,715 $64,882 Not Implemented
SF0580 # 01 Y:2021 01 2021 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $18,446 $0 Implemented
LS2207 # 05 Y:2022 05 2022 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $136,185 $2,775,000 Not Implemented
LS2206 # 04 Y:2022 04 2022 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $336 $250 Implemented
LS2206 # 01 Y:2022 01 2022 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,066 $10 Implemented
IC0253 # 05 Y:2022 05 2022 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $21,572 $7,624 Not Implemented
IC0253 # 02 Y:2022 02 2022 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $43,447 $8,510 Not Implemented
UU0195 # 05 Y:2022 05 2022 INSULATE BARE EQUIPMENT $3,620 $7,340 Not Implemented
TT0265 # 01 Y:2022 01 2022 INSULATE BARE EQUIPMENT $12,477 $2,065 Not Implemented
UA0249 # 05 Y:2021 05 2021 RECOVER WASTE HEAT FROM EQUIPMENT $5,261 $8,080 Implemented
MA0829 # 01 Y:2022 01 2022 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $34,736 $24,400 Not Implemented
MA0829 # 02 Y:2022 02 2022 INSULATE BARE EQUIPMENT $6,782 $8,620 Not Implemented
DL0199 # 10 Y:2021 10 2021 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,675 $7,837 Not Implemented
MA0829 # 06 Y:2022 06 2022 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $2,891 $4,445 Implemented