Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,064

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0183 # 05 Y:1990 05 1990 UTILIZE A LESS EXPENSIVE COOLING METHOD $10,356 $44,000 Implemented
KU0308 # 01 Y:1990 01 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $27,543 $23,000 Implemented
KU0309 # 07 Y:1990 07 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $22,428 $20,000 Not Implemented
KU0310 # 03 Y:1990 03 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $12,188 $18,000 Not Implemented
OR0081 # 01 Y:1990 01 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,762 $68,000 Implemented
OR0080 # 04 Y:1990 04 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,957 $0 Implemented
UD0309 # 06 Y:1990 06 1990 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,028 $10,000 Implemented
OR0076 # 07 Y:1990 07 1990 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,585 $6,190 Implemented
OR0076 # 05 Y:1990 05 1990 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,222 $3,600 Not Implemented
OR0074 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,200 $2,400 Not Implemented
OR0070 # 04 Y:1989 04 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,766 $0 Implemented
OR0073 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,597 $0 Implemented
GT0390 # 06 Y:1989 06 1989 USE COLD WASTE WATER TO COOL CHILLER FEED WATER $14,480 $16,950 Not Implemented
KU0298 # 05 Y:1989 05 1989 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,951 $3,700 Not Implemented
AM0075 # 04 Y:1989 04 1989 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $2,597 $1,000 Not Implemented
CO0166 # 07 Y:1989 07 1989 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $430 $100 Implemented
OR0067 # 07 Y:1989 07 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $6,141 $14,400 Not Implemented
CO0161 # 01 Y:1989 01 1989 AVOID FROST FORMATION ON EVAPORATORS $1,340 $3,000 Not Implemented
KU0294 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $7,667 $8,200 Not Implemented
KU0294 # 02 Y:1989 02 1989 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $16,418 $15,000 Not Implemented
WI0064 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $16,709 $0 Not Implemented
KU0287 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,214 $4,800 Not Implemented
KU0286 # 06 Y:1989 06 1989 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,815 $20,000 Implemented
KU0282 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,994 $3,600 Not Implemented
OR0056 # 01 Y:1989 01 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $252 $0 Implemented