Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19

matching recommendations
Reset
ARC 2.51 SYSTEMS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0018 # 05 Y:2007 05 2007 REDESIGN PROCESS $5,616 $0 Not Implemented
DL0009 # 02 Y:2007 02 2007 REDESIGN PROCESS $15,567 $6,300 Not Implemented
UM0333 # 05 Y:2007 05 2007 REDESIGN PROCESS $2,329 $3,480 Not Implemented
GT0844 # 08 Y:2007 08 2007 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $65,444 $81,971 Not Implemented
UF0406 # 04 Y:2007 04 2007 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $6,004 $399 Not Implemented
IC0134 # 02 Y:2007 02 2007 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $24,453 $77,470 Not Implemented
UW0008 # 01 Y:2007 01 2007 USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS $136,932 $492,147 Implemented
GT0842 # 02 Y:2007 02 2007 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $17,400 $27,000 Not Implemented
UW0005 # 02 Y:2007 02 2007 REPOSITION OVEN WALLS TO REDUCE HEATED SPACE $15,876 $4,452 Implemented
IC0130 # 01 Y:2007 01 2007 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $12,768 $40,352 Not Implemented
UM0322 # 07 Y:2007 07 2007 REDUCE FLUID FLOW RATES $1,434 $2,200 Not Implemented
WV0360 # 02 Y:2007 02 2007 CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS $44,169 $15,000 Not Implemented
GT0834 # 01 Y:2007 01 2007 MODIFY TEXTILE DRYERS $47,625 $36,000 Implemented
MZ0013 # 01 Y:2007 01 2007 USE CONTINUOUS EQUIPMENT WHICH RETAINS PROCESS HEATING CONVEYORS WITHIN THE HEATED CHAMBER $78,456 $300,000 Not Implemented
UF0397 # 04 Y:2007 04 2007 REDESIGN PROCESS $10,558 $8,150 Not Implemented
IC0125 # 09 Y:2007 09 2007 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $52,577 $43,780 Implemented
UF0395 # 10 Y:2007 10 2007 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH $77,607 $31,201 Implemented
LE0249 # 02 Y:2007 02 2007 REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS $61,899 $515,000 Implemented
AM0523 # 02 Y:2007 02 2007 REPOSITION OVEN WALLS TO REDUCE HEATED SPACE $11,700 $500 Implemented