Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,708
matching recommendationsARC | 2.72 | SPACE CONDITIONING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0411 # 10 Y:2008 | 10 | 2008 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,946 | $25,280 | Not Implemented |
UF0411 # 02 Y:2008 | 02 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $47,620 | $6,301 | Not Implemented |
UM0337 # 01 Y:2008 | 01 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $16,708 | $8,050 | Not Implemented |
AM0546 # 01 Y:2008 | 01 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $33,360 | $17,050 | Not Implemented |
UA0015 # 05 Y:2008 | 05 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $7,573 | $823 | Implemented |
IA0423 # 03 Y:2008 | 03 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,639 | $150 | Not Implemented |
IA0423 # 06 Y:2008 | 06 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,415 | $18,345 | Not Implemented |
AM0544 # 04 Y:2008 | 04 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,200 | $24,000 | Implemented |
LL0291 # 06 Y:2008 | 06 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $276 | $231 | Not Implemented |
NC0375 # 03 Y:2008 | 03 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,903 | $7,500 | Implemented |
MA0634 # 04 Y:2008 | 04 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,932 | $2,500 | Implemented |
MA0634 # 05 Y:2008 | 05 | 2008 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $1,034 | $6,000 | Not Implemented |
UD0783 # 09 Y:2008 | 09 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,818 | $5,000 | Not Implemented |
NC0373 # 02 Y:2008 | 02 | 2008 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $13,018 | $26,250 | Not Implemented |
NC0373 # 01 Y:2008 | 01 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,343 | $15,000 | Not Implemented |
WV0375 # 07 Y:2008 | 07 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $23,729 | $37,200 | Not Implemented |
MI0164 # 02 Y:2008 | 02 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $80,047 | $6,886 | Implemented |
UM0335 # 05 Y:2008 | 05 | 2008 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,221 | $500 | Implemented |
MA0632 # 03 Y:2008 | 03 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $4,818 | $19,300 | Not Implemented |
MA0632 # 02 Y:2008 | 02 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,185 | $17,080 | Not Implemented |
BD0340 # 08 Y:2008 | 08 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $8,829 | $30,001 | Not Implemented |
UF0410 # 04 Y:2008 | 04 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,229 | $233 | Implemented |
UF0409 # 01 Y:2008 | 01 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $11,798 | $16,755 | Not Implemented |
UF0409 # 02 Y:2008 | 02 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $8,549 | $1,248 | Implemented |
UF0409 # 09 Y:2008 | 09 | 2008 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $17,491 | $25,340 | Not Implemented |