Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,326
matching recommendationsARC | 2.1 | Combustion Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0444 # 01 Y:2012 | 01 | 2012 | ADJUST BURNERS FOR EFFICIENT OPERATION | $5,257 | $2,000 | Implemented |
NC0444 # 02 Y:2012 | 02 | 2012 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $3,445 | $8,500 | Not Implemented |
WV0440 # 04 Y:2012 | 04 | 2012 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,797 | $44,000 | Not Implemented |
UMS004 # 02 Y:2012 | 02 | 2012 | CONVERT TO OXYFUEL BURNERS | $156,000 | $250,000 | Not Implemented |
UMS004 # 05 Y:2012 | 05 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,500 | $0 | Not Implemented |
UD0849 # 08 Y:2012 | 08 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,274 | $2,000 | Not Implemented |
NC0443 # 02 Y:2012 | 02 | 2012 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $9,610 | $27,000 | Not Implemented |
SD0443 # 04 Y:2012 | 04 | 2012 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,443 | $618 | Implemented |
SU0316 # 10 Y:2012 | 10 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $48,724 | $900,000 | Not Implemented |
MZ0075 # 02 Y:2012 | 02 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,400 | $1,500 | Implemented |
GT0889 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,925 | $1,000 | Not Implemented |
BD0406 # 11 Y:2012 | 11 | 2012 | INSTALL TURBULATORS | $772 | $1,500 | Implemented |
BD0406 # 03 Y:2012 | 03 | 2012 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $12,730 | $10,000 | Not Implemented |
SF0406 # 09 Y:2012 | 09 | 2012 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $2,696 | $10,439 | Not Implemented |
SF0406 # 08 Y:2012 | 08 | 2012 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $25,304 | $93,999 | Not Implemented |
UA0072 # 07 Y:2012 | 07 | 2012 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,750 | $415 | Not Implemented |
UD0846 # 06 Y:2012 | 06 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,109 | $1,000 | Not Implemented |
SF0405 # 09 Y:2012 | 09 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $112,997 | $524,700 | Not Implemented |
UMS001 # 01 Y:2012 | 01 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $986,100 | $900,000 | Not Implemented |
BD0404 # 01 Y:2012 | 01 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $49,969 | $32,000 | Not Implemented |
UMS001 # 02 Y:2012 | 02 | 2012 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $782,000 | $1,377,000 | Not Implemented |
UMS001 # 04 Y:2012 | 04 | 2012 | ADJUST BURNERS FOR EFFICIENT OPERATION | $13,000 | $15,000 | Not Implemented |
NC0441 # 07 Y:2012 | 07 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $350 | $800 | Implemented |
NC0441 # 09 Y:2012 | 09 | 2012 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $1,800 | $1,000 | Not Implemented |
IC0192 # 07 Y:2011 | 07 | 2011 | ADJUST BURNERS FOR EFFICIENT OPERATION | $3,224 | $1,612 | n/a |