Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,326

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0395 # 06 Y:2009 06 2009 KEEP BOILER TUBES CLEAN $826 $1,000 Not Implemented
UD0804 # 08 Y:2009 08 2009 KEEP BOILER TUBES CLEAN $8,490 $600 Implemented
OK0780 # 03 Y:2009 03 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $155,286 $17,711 Not Implemented
OK0780 # 02 Y:2009 02 2009 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $66,265 $0 Implemented
OK0780 # 01 Y:2009 01 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $134,300 $0 Implemented
UD0804 # 05 Y:2009 05 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $17,277 $500 Implemented
IC0160 # 10 Y:2009 10 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $179 $0 Implemented
WV0394 # 06 Y:2009 06 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,269 $600 Implemented
WV0394 # 01 Y:2009 01 2009 CONVERT TO OXYFUEL BURNERS $81,984 $49,000 Not Implemented
TT0039 # 05 Y:2009 05 2009 IMPROVE COMBUSTION CONTROL CAPABILITY $112,568 $64,000 Not Implemented
UD0803 # 09 Y:2009 09 2009 KEEP BOILER TUBES CLEAN $4,480 $1,000 Implemented
UD0803 # 06 Y:2009 06 2009 REDUCE EXCESSIVE BOILER BLOWDOWN $9,743 $4,500 Not Implemented
UD0803 # 07 Y:2009 07 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,851 $500 Not Implemented
UF0426 # 02 Y:2009 02 2009 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $146,810 $3,192 Not Implemented
UD0802 # 04 Y:2009 04 2009 INSTALL AUTOMATIC STACK DAMPER $3,637 $1,000 Not Implemented
OR0546 # 02 Y:2009 02 2009 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $24,190 $17,000 Not Implemented
OR0546 # 01 Y:2009 01 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,000 $350 Not Implemented
LE0290 # 08 Y:2009 08 2009 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $1,204 $2,500 Implemented
LE0289 # 01 Y:2009 01 2009 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $19,778 $20,000 Implemented
SU0284 # 03 Y:2009 03 2009 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $62,238 $73,214 Implemented
MA0651 # 06 Y:2009 06 2009 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $4,725 $18,300 Not Implemented
MA0651 # 03 Y:2009 03 2009 REPLACE BOILER $10,080 $30,700 Implemented
IA0441 # 09 Y:2009 09 2009 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $49,777 $70,000 Not Implemented
UW0030 # 02 Y:2009 02 2009 KEEP BOILER TUBES CLEAN $115,460 $50,000 Not Implemented
IC0157 # 09 Y:2009 09 2009 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,416 $210 Not Implemented