IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

252

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0336 # 01 Y:2004 01 2004 REDUCE EXCESSIVE BOILER BLOWDOWN $3,854 $4,300 Implemented
LE0179 # 05 Y:2004 05 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $960 $750 Not Implemented
GT0777 # 08 Y:2004 08 2004 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $13,327 $20,670 n/a
GT0776 # 01 Y:2004 01 2004 CONTROL PRESSURE ON STEAMER OPERATIONS $1,335 $0 n/a
NC0277 # 06 Y:2004 06 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $1,049 $1,000 Implemented
GT0776 # 11 Y:2004 11 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $18,496 $100,000 n/a
GT0776 # 10 Y:2004 10 2004 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $9,120 $16,200 n/a
OR0451 # 05 Y:2004 05 2004 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $875 $300 Not Implemented
BD0253 # 03 Y:2004 03 2004 INSTALL AUTOMATIC STACK DAMPER $2,979 $5,500 Implemented
BD0253 # 09 Y:2004 09 2004 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,807 $6,000 Not Implemented
BD0253 # 08 Y:2004 08 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,816 $2,400 Implemented
WV0283 # 01 Y:2004 01 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $11,512 $250 Implemented
LE0178 # 03 Y:2004 03 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,543 $750 Not Implemented
UM0246 # 01 Y:2004 01 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $34,080 $26,630 Not Implemented
BD0252 # 07 Y:2004 07 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $701 $1,100 Implemented
LM0068 # 05 Y:2004 05 2004 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $1,181 $260 Implemented
LM0068 # 08 Y:2004 08 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $40,318 $55,000 Not Implemented
MS0242 # 05 Y:2004 05 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,122 $300 Not Implemented
UM0245 # 02 Y:2004 02 2004 REPLACE BOILER $13,000 $34,000 Not Implemented
AS0367 # 03 Y:2004 03 2004 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,275 $4,395 Not Implemented
BD0250 # 07 Y:2004 07 2004 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,244 $2,500 Not Implemented
LE0177 # 02 Y:2004 02 2004 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $2,947 $5,000 Not Implemented
LE0176 # 03 Y:2004 03 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $19,851 $1,000 Not Implemented
LE0176 # 04 Y:2004 04 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $14,480 $5,000 Not Implemented
LE0176 # 07 Y:2004 07 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $985 $0 Not Implemented