Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

168

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0728 # 02 Y:2014 02 2014 REPLACE BOILER $10,114 $30,450 Implemented
SD0484 # 01 Y:2014 01 2014 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $111,951 $87,500 Not Implemented
UA0121 # 03 Y:2014 03 2014 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $27,986 $37,058 Not Implemented
MA0729 # 01 Y:2014 01 2014 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $25,718 $11,750 Not Implemented
LE0381 # 11 Y:2014 11 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,146 $3,000 Not Implemented
LE0381 # 12 Y:2014 12 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,362 $16,000 Not Implemented
UD0902 # 03 Y:2014 03 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $828 $0 Not Implemented
UD0902 # 09 Y:2014 09 2014 BURN A LESS EXPENSIVE GRADE OF FUEL $9,848 $0 Not Implemented
UM0444 # 03 Y:2014 03 2014 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $67,306 $80,000 Not Implemented
UM0444 # 05 Y:2014 05 2014 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $104,300 $208,000 Not Implemented
NC0510 # 01 Y:2014 01 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $55,430 $1,200 Implemented
UA0119 # 04 Y:2014 04 2014 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $34,015 $23,300 Not Implemented
DL0129 # 07 Y:2014 07 2014 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,806 $0 Implemented
DL0128 # 02 Y:2014 02 2014 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $28,000 $50,000 Not Implemented
DL0128 # 05 Y:2014 05 2014 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $6,000 $20,000 Implemented
DL0127 # 04 Y:2014 04 2014 REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS $1,200 $1,800 Not Implemented
BS0031 # 03 Y:2014 03 2014 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $3,665 $2,000 Not Implemented
DL0126 # 04 Y:2014 04 2014 ADJUST BURNERS FOR EFFICIENT OPERATION $15,000 $50,000 Not Implemented
OR0628 # 01 Y:2014 01 2014 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $44,216 $17,353 Not Implemented
DL0126 # 05 Y:2014 05 2014 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $11,910 $8,200 Not Implemented
DL0126 # 08 Y:2014 08 2014 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $7,300 $16,000 Not Implemented
DL0126 # 09 Y:2014 09 2014 REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE $3,900 $6,300 Not Implemented
WV0485 # 02 Y:2014 02 2014 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $9,166 $12,500 Not Implemented
WV0485 # 05 Y:2014 05 2014 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,703 $500 Implemented
DL0125 # 03 Y:2014 03 2014 IMPROVE COMBUSTION CONTROL CAPABILITY $43,100 $100 Not Implemented