Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
148
matching recommendationsARC | 2.12 | BOILERS |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0515 # 01 Y:1993 | 01 | 1993 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $4,130 | $9,570 | Not Implemented |
GT0515 # 02 Y:1993 | 02 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,090 | $0 | Not Implemented |
GT0514 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,450 | $900 | Implemented |
IA0072 # 06 Y:1993 | 06 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $585 | $500 | Not Implemented |
SF0015 # 06 Y:1993 | 06 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,540 | $400 | Implemented |
AS0105 # 07 Y:1993 | 07 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $551 | $500 | Not Implemented |
KU0419 # 03 Y:1993 | 03 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $10,041 | $15,400 | Not Implemented |
CO0290 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,350 | $2,500 | Not Implemented |
OK0421 # 02 Y:1993 | 02 | 1993 | REPLACE BOILER | $1,806 | $4,325 | Not Implemented |
GT0510 # 06 Y:1993 | 06 | 1993 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $134,080 | $250,000 | Implemented |
ME0117 # 05 Y:1993 | 05 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,071 | $900 | Not Implemented |
ME0115 # 01 Y:1993 | 01 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,628 | $800 | Not Implemented |
OR0194 # 01 Y:1993 | 01 | 1993 | KEEP BOILER TUBES CLEAN | $23,338 | $2,500 | Implemented |
MO0104 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,658 | $1,695 | Implemented |
MO0103 # 07 Y:1993 | 07 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,195 | $1,195 | Implemented |
GT0509 # 06 Y:1993 | 06 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,569 | $450 | Implemented |
WI0193 # 02 Y:1993 | 02 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,243 | $5,000 | Not Implemented |
WI0193 # 01 Y:1993 | 01 | 1993 | OPERATE BOILERS ON HIGH FIRE SETTING | $11,935 | $4,500 | Implemented |
OR0193 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $29,170 | $5,000 | Implemented |
IA0071 # 06 Y:1993 | 06 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $501 | $612 | Not Implemented |
UD0415 # 03 Y:1993 | 03 | 1993 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $200,000 | $480,000 | Not Implemented |
AS0103 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,038 | $13,000 | Implemented |
OR0192 # 01 Y:1993 | 01 | 1993 | KEEP BOILER TUBES CLEAN | $26,620 | $4,000 | Implemented |
WI0191 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $959 | $500 | Implemented |
WI0191 # 04 Y:1993 | 04 | 1993 | OPERATE BOILERS ON HIGH FIRE SETTING | $1,499 | $0 | Implemented |