Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsARC | 2.12 | BOILERS |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0958 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,461 | $2,000 | Implemented |
OK0951 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,904 | $3,000 | Implemented |
BD0493 # 02 Y:2016 | 02 | 2016 | REPLACE BOILER | $7,259 | $14,000 | n/a |
BD0493 # 03 Y:2016 | 03 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,620 | $6,000 | n/a |
BS0092 # 04 Y:2016 | 04 | 2016 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,190 | $6,640 | Not Implemented |
OK0956 # 01 Y:2016 | 01 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,844 | $7,700 | Not Implemented |
MA0766 # 01 Y:2016 | 01 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,264 | $57,500 | Not Implemented |
IP0074 # 05 Y:2016 | 05 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,366 | $308 | Implemented |
IA0566 # 06 Y:2016 | 06 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,284 | $1,000 | Implemented |
OR0679 # 06 Y:2016 | 06 | 2016 | REPLACE BOILER | $48,912 | $250,000 | Not Implemented |
NC0576 # 01 Y:2016 | 01 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,790 | $3,000 | Implemented |
SF0492 # 07 Y:2016 | 07 | 2016 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,867 | $11,727 | Implemented |
BS0086 # 02 Y:2016 | 02 | 2016 | REPLACE BOILER | $4,643 | $61,724 | Not Implemented |
WV0534 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,026 | $4,100 | Implemented |
OR0677 # 03 Y:2016 | 03 | 2016 | REPLACE BOILER | $4,164 | $17,322 | Not Implemented |
UD0956 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,229 | $0 | Not Implemented |
UD0956 # 03 Y:2016 | 03 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,897 | $12,000 | Not Implemented |
UD0956 # 01 Y:2016 | 01 | 2016 | INSTALL TURBULATORS | $15,641 | $5,625 | Not Implemented |
OK0949 # 05 Y:2016 | 05 | 2016 | OPERATE BOILERS ON HIGH FIRE SETTING | $10,228 | $44,000 | Not Implemented |
SU0420 # 05 Y:2016 | 05 | 2016 | REPLACE BOILER | $5,360 | $420 | Not Implemented |
IA0563 # 05 Y:2016 | 05 | 2016 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,962 | $4,050 | Not Implemented |
WV0533 # 03 Y:2016 | 03 | 2016 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $15,212 | $35,900 | Implemented |
WV0533 # 08 Y:2016 | 08 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,301 | $4,100 | Not Implemented |
IA0562 # 04 Y:2016 | 04 | 2016 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,205 | $2,457 | Implemented |
WV0531 # 01 Y:2016 | 01 | 2016 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $19,064 | $33,000 | Not Implemented |