Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,769

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0171 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $4,085 $761 Implemented
WV0171 # 06 Y:1999 06 1999 REPAIR AND ELIMINATE STEAM LEAKS $10,816 $730 Implemented
WV0171 # 07 Y:1999 07 1999 REPAIR OR REPLACE STEAM TRAPS $5,382 $1,690 Implemented
HO0206 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $2,390 $2,840 Implemented
WV0170 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $2,084 $98 Implemented
DS0136 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $1,921 $1,137 Implemented
SF0169 # 08 Y:1999 08 1999 INSULATE BARE EQUIPMENT $791 $2,991 Implemented
SF0169 # 11 Y:1999 11 1999 USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS $55,556 $17,250 Implemented
TN0662 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,010 $1,460 Implemented
WV0168 # 01 Y:1999 01 1999 INSULATE BARE EQUIPMENT $5,946 $5,087 Implemented
WI0350 # 06 Y:1999 06 1999 RECOVER WASTE HEAT FROM EQUIPMENT $474 $500 Implemented
CO0439 # 01 Y:1999 01 1999 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $187,200 $13,080 Implemented
GT0664 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $13,210 $19,500 Implemented
MA0441 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $632 $2,250 Implemented
HO0204 # 06 Y:1999 06 1999 INSULATE FEEDWATER TANK $526 $438 Implemented
MA0440 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $3,278 $5,204 Implemented
ME0267 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $7,078 $3,870 Implemented
ND0323 # 12 Y:1999 12 1999 USE OPTIMUM TEMPERATURE $32 $10 Implemented
SD0225 # 04 Y:1999 04 1999 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $704 $400 Implemented
WV0167 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $5,901 $606 Implemented
WV0166 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $24,192 $5,439 Implemented
ND0322 # 02 Y:1999 02 1999 USE OPTIMUM TEMPERATURE $161 $0 Implemented
WV0164 # 07 Y:1999 07 1999 RECOVER WASTE HEAT FROM EQUIPMENT $918 $428 Implemented
NV0128 # 01 Y:1999 01 1999 INSULATE BARE EQUIPMENT $21,114 $38,248 Implemented
DS0141 # 01 Y:1999 01 1999 PREHEAT COMBUSTION AIR WITH WASTE HEAT $10,285 $24,040 Implemented