Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,004
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0272 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,828 | $1,000 | Implemented |
NC0306 # 01 Y:2004 | 01 | 2004 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $96,975 | $360,700 | Not Implemented |
LE0204 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,339 | $6,000 | Not Implemented |
MA0568 # 06 Y:2005 | 06 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,459 | $2,888 | Not Implemented |
LE0204 # 02 Y:2005 | 02 | 2005 | INSULATE FEEDWATER TANK | $18,286 | $8,304 | Implemented |
UD0709 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,549 | $34,600 | Not Implemented |
OK0700 # 01 Y:2005 | 01 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $78,457 | $36,299 | Not Implemented |
UD0709 # 05 Y:2005 | 05 | 2005 | INSULATE BARE EQUIPMENT | $3,977 | $4,500 | Implemented |
OK0700 # 08 Y:2005 | 08 | 2005 | INSULATE BARE EQUIPMENT | $5,958 | $2,709 | Not Implemented |
OK0700 # 09 Y:2005 | 09 | 2005 | INSULATE BARE EQUIPMENT | $942 | $2,046 | Not Implemented |
OR0478 # 04 Y:2005 | 04 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,800 | $0 | Not Implemented |
OR0477 # 08 Y:2005 | 08 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $48,200 | $0 | Implemented |
OR0477 # 03 Y:2005 | 03 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $28,455 | $11,500 | Implemented |
OR0477 # 07 Y:2005 | 07 | 2005 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $29,545 | $182,000 | Not Implemented |
LE0203 # 08 Y:2005 | 08 | 2005 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $864 | $0 | Not Implemented |
LE0203 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $34,823 | $36,750 | Implemented |
BD0278 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,148 | $2,000 | Implemented |
AM0477 # 02 Y:2005 | 02 | 2005 | INSULATE BARE EQUIPMENT | $4,060 | $485 | Not Implemented |
AM0477 # 05 Y:2005 | 05 | 2005 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $5,200 | $4,300 | Not Implemented |
BD0277 # 04 Y:2005 | 04 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,514 | $1,200 | Implemented |
BD0275 # 05 Y:2005 | 05 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,674 | $6,000 | Not Implemented |
MS0266 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $42,481 | $15,060 | Not Implemented |
MS0266 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN HIGH PRESSURE REDUCING STATIONS | $10,281 | $73 | Not Implemented |
OR0475 # 03 Y:2005 | 03 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,300 | $0 | Not Implemented |
OR0475 # 04 Y:2005 | 04 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,700 | $0 | Not Implemented |