Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
510
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0210 # 02 Y:1998 | 02 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,040 | $12,186 | Not Implemented |
KU0506 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $25,360 | $25,360 | n/a |
DS0125 # 03 Y:1998 | 03 | 1998 | INSULATE BARE EQUIPMENT | $11,394 | $2,450 | Not Implemented |
ME0255 # 08 Y:1998 | 08 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,945 | $2,860 | Implemented |
GT0645 # 02 Y:1998 | 02 | 1998 | USE MINIMUM SAFE OVEN VENTILATION | $2,720 | $0 | Not Implemented |
GT0645 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,810 | $7,000 | Implemented |
UL0203 # 02 Y:1998 | 02 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,100 | $20,100 | Not Implemented |
ND0315 # 07 Y:1998 | 07 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,283 | $38,500 | Not Implemented |
MS0121 # 07 Y:1998 | 07 | 1998 | INSULATE BARE EQUIPMENT | $2,615 | $104 | Implemented |
MA0419 # 01 Y:1998 | 01 | 1998 | COVER OPEN TANKS | $168,295 | $5,000 | Implemented |
UF0211 # 08 Y:1998 | 08 | 1998 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $14,651 | $28,996 | Not Implemented |
OK0556 # 02 Y:1998 | 02 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $227 | $678 | Implemented |
OK0556 # 03 Y:1998 | 03 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $1,303 | $500 | Implemented |
TN0644 # 05 Y:1998 | 05 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,575 | $8,575 | Not Implemented |
TN0644 # 07 Y:1998 | 07 | 1998 | INSULATE BARE EQUIPMENT | $2,850 | $1,100 | Not Implemented |
WI0334 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,932 | $6,000 | Not Implemented |
ND0316 # 07 Y:1998 | 07 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,405 | $250 | Not Implemented |
ND0316 # 01 Y:1998 | 01 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,390 | $46,000 | Not Implemented |
NC0151 # 04 Y:1998 | 04 | 1998 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $700 | $2,100 | Not Implemented |
NC0145 # 01 Y:1998 | 01 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,611 | $25,000 | Not Implemented |
NC0145 # 02 Y:1998 | 02 | 1998 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $33,755 | $125,000 | Not Implemented |
WV0154 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $16,667 | $9,432 | Not Implemented |
WV0154 # 03 Y:1998 | 03 | 1998 | INSULATE BARE EQUIPMENT | $4,282 | $5,130 | Not Implemented |
WV0154 # 04 Y:1998 | 04 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $322 | $482 | Not Implemented |
WV0154 # 05 Y:1998 | 05 | 1998 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $162 | $550 | Not Implemented |