Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

497

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0357 # 04 Y:1999 04 1999 UTILIZE A LESS EXPENSIVE COOLING METHOD $198,470 $500,000 Not Implemented
OR0357 # 05 Y:1999 05 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $7,150 $0 Implemented
OD0147 # 04 Y:1999 04 1999 REPAIR OR REPLACE STEAM TRAPS $1,854 $360 Not Implemented
KU0532 # 01 Y:1999 01 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,410 $17,000 Not Implemented
AR0172 # 01 Y:1999 01 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $158 $238 Not Implemented
KU0530 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $620 $730 n/a
CO0451 # 01 Y:1999 01 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $7,190 $6,250 Not Implemented
GT0673 # 04 Y:1999 04 1999 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $3,118 $5,050 Not Implemented
UF0227 # 01 Y:1999 01 1999 USE OPTIMUM THICKNESS INSULATION $7,828 $0 Not Implemented
BD0138 # 03 Y:1999 03 1999 COVER OPEN TANKS $2,467 $5,000 Not Implemented
BD0145 # 02 Y:1999 02 1999 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,654 $6,000 Implemented
ND0336 # 04 Y:1999 04 1999 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $126 $150 Not Implemented
BD0143 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $12,500 $21,400 Not Implemented
BD0143 # 09 Y:1999 09 1999 RECOVER WASTE HEAT FROM EQUIPMENT $6,405 $25,000 Not Implemented
ORS005 # 03 Y:1999 03 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $55,755 $0 Implemented
ORS005 # 04 Y:1999 04 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $18,500 $40,000 Implemented
SD0229 # 06 Y:1999 06 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,372 $540 Not Implemented
ORS004 # 01 Y:1999 01 1999 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $24,048 $0 Implemented
SF0172 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $1,121 $825 Implemented
SF0172 # 09 Y:1999 09 1999 RECOVER WASTE HEAT FROM EQUIPMENT $8,448 $21,777 Implemented
NC0172 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $636 $476 Not Implemented
NC0172 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $71,741 $40,000 Not Implemented
ME0275 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,457 $1,191 Not Implemented
ND0338 # 07 Y:1999 07 1999 COVER OPEN TANKS $292 $400 Not Implemented
KU0528 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $3,690 $4,240 n/a