Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,000

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0058 # 03 Y:2003 03 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,012 $18,500 Not Implemented
NC0256 # 05 Y:2003 05 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,851 $30,000 Not Implemented
NC0256 # 06 Y:2003 06 2003 INSULATE BARE EQUIPMENT $2,112 $4,375 Implemented
NC0256 # 04 Y:2003 04 2003 RECOVER WASTE HEAT FROM EQUIPMENT $5,417 $12,587 Not Implemented
OK0658 # 06 Y:2003 06 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $30,454 $60,000 Not Implemented
NC0255 # 03 Y:2003 03 2003 RECOVER WASTE HEAT FROM EQUIPMENT $4,159 $5,600 Not Implemented
NC0255 # 05 Y:2003 05 2003 REPAIR AND ELIMINATE STEAM LEAKS $2,425 $350 Implemented
BD0230 # 07 Y:2003 07 2003 INSULATE FEEDWATER TANK $101 $125 Implemented
BD0230 # 01 Y:2003 01 2003 PREHEAT COMBUSTION AIR WITH WASTE HEAT $8,785 $26,000 Not Implemented
LE0152 # 02 Y:2003 02 2003 USE CASCADE SYSTEM OF RECIRCULATING DURING COLD WEATHER TO AVOID SUB-COOLING $1,150 $1,000 Not Implemented
SD0315 # 02 Y:2003 02 2003 ISOLATE HOT OR COLD EQUIPMENT $30,227 $5,000 Not Implemented
WV0263 # 08 Y:2003 08 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,365 $1,755 Not Implemented
TA0051 # 02 Y:2003 02 2003 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $53,166 $17,450 Implemented
LE0144 # 04 Y:2002 04 2002 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $968 $0 Not Implemented
UU0042 # 08 Y:2003 08 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $14,607 $100,240 Not Implemented
UU0042 # 07 Y:2003 07 2003 RECOVER WASTE HEAT FROM EQUIPMENT $792 $2,296 Not Implemented
WV0263 # 09 Y:2003 09 2003 INSULATE BARE EQUIPMENT $378 $873 Implemented
WV0262 # 01 Y:2003 01 2003 INSULATE BARE EQUIPMENT $1,233 $659 Implemented
UU0041 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $1,080 $950 n/a
NC0254 # 05 Y:2003 05 2003 COVER OPEN TANKS $14,740 $0 Not Implemented
GT0750 # 08 Y:2003 08 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,570 $27,000 Not Implemented
TA0050 # 02 Y:2003 02 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $47,100 $5,202 Implemented
WV0262 # 07 Y:2003 07 2003 RECOVER WASTE HEAT FROM EQUIPMENT $1,748 $240 Not Implemented
IC0056 # 06 Y:2003 06 2003 REPAIR AND ELIMINATE STEAM LEAKS $17,396 $3,500 Not Implemented
WV0262 # 14 Y:2003 14 2003 REPAIR OR REPLACE STEAM TRAPS $3,018 $1,000 Implemented