Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,000
matching recommendationsARC | 2.2 | Thermal Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0186 # 03 Y:2000 | 03 | 2000 | INSULATE BARE EQUIPMENT | $100 | $138 | Implemented |
ND0347 # 06 Y:2000 | 06 | 2000 | USE OPTIMUM TEMPERATURE | $10 | $8 | Implemented |
WV0186 # 04 Y:2000 | 04 | 2000 | ISOLATE HOT OR COLD EQUIPMENT | $655 | $1,580 | Not Implemented |
DS0162 # 01 Y:2000 | 01 | 2000 | USE OPTIMUM THICKNESS INSULATION | $4,196 | $3,997 | n/a |
WV0189 # 02 Y:2000 | 02 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,448 | $0 | Not Implemented |
TN0682 # 07 Y:2000 | 07 | 2000 | COVER OPEN TANKS | $505 | $800 | Not Implemented |
OD0157 # 03 Y:2000 | 03 | 2000 | REPAIR OR REPLACE STEAM TRAPS | $4,241 | $1,420 | Implemented |
OD0158 # 05 Y:2000 | 05 | 2000 | REPAIR OR REPLACE STEAM TRAPS | $20,642 | $4,920 | Implemented |
ME0289 # 02 Y:2000 | 02 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,387 | $3,165 | Implemented |
UD0593 # 04 Y:2000 | 04 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,243 | $6,080 | Implemented |
AM0370 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $26,200 | $2,200 | Not Implemented |
SD0243 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $4,293 | $9,936 | Implemented |
SD0243 # 01 Y:2000 | 01 | 2000 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $17,132 | $28,575 | Not Implemented |
SD0243 # 09 Y:2000 | 09 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,098 | $500 | Implemented |
SD0243 # 10 Y:2000 | 10 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $953 | $2,425 | Not Implemented |
MA0462 # 02 Y:2000 | 02 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $194,677 | $430,350 | Not Implemented |
CO0461 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,130 | $2,250 | Not Implemented |
DS0161 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $758 | $1,130 | Implemented |
ME0288 # 05 Y:2000 | 05 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,832 | $9,423 | Implemented |
TP0015 # 09 Y:2000 | 09 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $334 | $301 | Not Implemented |
TN0678 # 09 Y:2000 | 09 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $277 | $0 | Implemented |
TN0678 # 08 Y:2000 | 08 | 2000 | REDUCE EXCESS STEAM BLEEDING | $350 | $170 | Implemented |
WV0188 # 08 Y:2000 | 08 | 2000 | USE OPTIMUM THICKNESS INSULATION | $73 | $176 | Not Implemented |
WI0371 # 07 Y:2000 | 07 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,030 | $6,090 | Not Implemented |
MS0155 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,073 | $2,808 | n/a |