Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

660

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0279 # 05 Y:2003 05 2003 RECOVER WASTE HEAT FROM EQUIPMENT $5,983 $165 Not Implemented
OR0437 # 05 Y:2003 05 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $9,910 $14,200 Implemented
UM0243 # 02 Y:2003 02 2003 INSULATE BARE EQUIPMENT $20,715 $4,565 Not Implemented
NC0265 # 04 Y:2003 04 2003 RECOVER WASTE HEAT FROM EQUIPMENT $5,206 $1,100 Not Implemented
OR0436 # 05 Y:2003 05 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $48,169 $66,400 Implemented
SU0167 # 06 Y:2003 06 2003 RECOVER WASTE HEAT FROM EQUIPMENT $6,319 $5,775 Not Implemented
IA0328 # 07 Y:2003 07 2003 INSULATE BARE EQUIPMENT $446 $1,365 Not Implemented
IA0328 # 08 Y:2003 08 2003 INSULATE BARE EQUIPMENT $572 $1,552 Not Implemented
LE0164 # 04 Y:2003 04 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $175 $98 Not Implemented
MI0067 # 03 Y:2003 03 2003 COVER OPEN TANKS $62 $120 Implemented
UD0681 # 03 Y:2003 03 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,200 $8,060 Not Implemented
UD0681 # 11 Y:2003 11 2003 INSULATE BARE EQUIPMENT $930 $1,360 Implemented
WI0452 # 08 Y:2003 08 2003 USE OPTIMUM THICKNESS INSULATION $1,592 $687 Not Implemented
SF0268 # 03 Y:2003 03 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $19,165 $10,225 Not Implemented
SF0268 # 07 Y:2003 07 2003 INSULATE FEEDWATER TANK $527 $1,186 Not Implemented
CO0530 # 01 Y:2003 01 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $13,370 $10,000 Implemented
NC0266 # 05 Y:2003 05 2003 RECOVER WASTE HEAT FROM EQUIPMENT $1,833 $1,189 Implemented
NC0266 # 06 Y:2003 06 2003 INSULATE BARE EQUIPMENT $61 $132 Implemented
UM0242 # 05 Y:2003 05 2003 INSULATE BARE EQUIPMENT $4,180 $645 Not Implemented
WV0278 # 02 Y:2003 02 2003 REPAIR AND ELIMINATE STEAM LEAKS $27,508 $204 Implemented
WV0278 # 03 Y:2003 03 2003 REPAIR OR REPLACE STEAM TRAPS $23,200 $1,000 Implemented
WV0278 # 06 Y:2003 06 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,072 $1,915 Not Implemented
WV0278 # 07 Y:2003 07 2003 REDUCE EXCESS STEAM BLEEDING $9,439 $37,100 Not Implemented
WV0278 # 10 Y:2003 10 2003 INSULATE BARE EQUIPMENT $3,709 $258 Implemented
WV0277 # 06 Y:2003 06 2003 REPAIR AND ELIMINATE STEAM LEAKS $40,926 $450 Implemented