Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

563

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0277 # 01 Y:1996 01 1996 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $18,642 $10,000 Not Implemented
OD0069 # 04 Y:1996 04 1996 COVER OPEN TANKS $1,328 $1,030 Not Implemented
MA0373 # 02 Y:1996 02 1996 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,884 $705 Not Implemented
MA0373 # 05 Y:1996 05 1996 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $587 $2,000 Not Implemented
DS0064 # 03 Y:1996 03 1996 INSULATE BARE EQUIPMENT $1,299 $1,675 Not Implemented
GT0595 # 06 Y:1996 06 1996 USE MINIMUM STEAM OPERATING PRESSURE $124,000 $27,000 Not Implemented
MS0065 # 03 Y:1996 03 1996 RECOVER WASTE HEAT FROM EQUIPMENT $2,380 $4,484 Not Implemented
MS0065 # 04 Y:1996 04 1996 RECOVER WASTE HEAT FROM EQUIPMENT $2,297 $2,580 Not Implemented
WI0276 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $1,122 $2,310 Not Implemented
WV0100 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $1,680 $2,290 Implemented
WV0100 # 07 Y:1996 07 1996 INSULATE BARE EQUIPMENT $545 $656 Not Implemented
BD0066 # 02 Y:1996 02 1996 RECOVER WASTE HEAT FROM EQUIPMENT $4,399 $3,000 n/a
ND0251 # 10 Y:1996 10 1996 RECOVER WASTE HEAT FROM EQUIPMENT $2,510 $360 n/a
IA0153 # 02 Y:1996 02 1996 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $5,206 $22,090 Not Implemented
IA0153 # 08 Y:1996 08 1996 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,124 $4,500 Not Implemented
MA0372 # 04 Y:1996 04 1996 RECOVER WASTE HEAT FROM EQUIPMENT $6,420 $9,000 Not Implemented
MA0372 # 06 Y:1996 06 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $1,195 $645 Not Implemented
MA0372 # 07 Y:1996 07 1996 MODERATE COOLING TOWER OUTLET TEMPERATURE $2,124 $5,084 Not Implemented
ME0198 # 04 Y:1996 04 1996 RECOVER WASTE HEAT FROM EQUIPMENT $2,150 $2,150 Implemented
ME0198 # 08 Y:1996 08 1996 INSULATE BARE EQUIPMENT $8,789 $500 Not Implemented
ME0198 # 09 Y:1996 09 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $856 $646 Implemented
OR0271 # 01 Y:1996 01 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,100 $0 Not Implemented
OR0274 # 04 Y:1996 04 1996 HEAT WATER WITH EXHAUST HEAT $9,179 $27,349 Not Implemented
OR0274 # 06 Y:1996 06 1996 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $16,129 $30,000 Not Implemented
GT0594 # 05 Y:1996 05 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $112,836 $405,000 Implemented