Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,126

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0224 # 07 Y:2003 07 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $26,018 $50,000 n/a
SD0325 # 06 Y:2003 06 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $14,542 $0 Not Implemented
NC0259 # 10 Y:2003 10 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $2,785 $12,240 Implemented
NC0259 # 09 Y:2003 09 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,286 $10,000 Not Implemented
GT0758 # 04 Y:2003 04 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,438 $31,350 n/a
UF0321 # 04 Y:2003 04 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $7,451 $740 Not Implemented
OK0661 # 08 Y:2003 08 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $13,061 $45,000 Implemented
MA0532 # 08 Y:2003 08 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $520 $0 Not Implemented
OK0658 # 06 Y:2003 06 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $30,454 $60,000 Not Implemented
LE0152 # 02 Y:2003 02 2003 USE CASCADE SYSTEM OF RECIRCULATING DURING COLD WEATHER TO AVOID SUB-COOLING $1,150 $1,000 Not Implemented
UU0042 # 08 Y:2003 08 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $14,607 $100,240 Not Implemented
LE0144 # 04 Y:2002 04 2002 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $968 $0 Not Implemented
GT0750 # 08 Y:2003 08 2003 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,570 $27,000 Not Implemented
UU0040 # 02 Y:2003 02 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $150 $0 Not Implemented
SD0318 # 02 Y:2003 02 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,503 $25,000 Not Implemented
WV0259 # 12 Y:2003 12 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $217 $50 Implemented
SF0255 # 03 Y:2003 03 2003 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $7,212 $5,250 Not Implemented
CO0521 # 01 Y:2003 01 2003 UTILIZE A LESS EXPENSIVE COOLING METHOD $65,190 $82,000 Not Implemented
WV0257 # 14 Y:2003 14 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $954 $110 Implemented
GT0747 # 07 Y:2003 07 2003 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $7,662 $1,500 Implemented
AM0431 # 03 Y:2003 03 2003 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $3,480 $5,640 Implemented
SF0253 # 02 Y:2003 02 2003 USE MULTIPLE-EFFECT EVAPORATORS $88,799 $75,000 Not Implemented
AS0344 # 05 Y:2003 05 2003 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $82 $356 Implemented
MA0527 # 07 Y:2003 07 2003 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $1,300 $0 Not Implemented
AS0343 # 05 Y:2003 05 2003 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $12,973 $30,140 Not Implemented