Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

36

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0165 # 01 Y:1992 01 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $4,045 $500 Implemented
OR0165 # 05 Y:1992 05 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $830 $0 Implemented
OR0164 # 02 Y:1992 02 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $1,608 $0 Implemented
AS0072 # 01 Y:1992 01 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $9,429 $20,000 Not Implemented
AS0073 # 05 Y:1992 05 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,124 $6,200 Implemented
AS0075 # 10 Y:1992 10 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,506 $10,500 Not Implemented
CO0250 # 12 Y:1992 12 1992 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $240 $1,120 Implemented
CO0250 # 11 Y:1992 11 1992 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $140 $240 Implemented
UF0040 # 06 Y:1992 06 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,115 $17,600 Not Implemented
OR0156 # 04 Y:1992 04 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $200 $0 Implemented
KU0377 # 08 Y:1992 08 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $617 $1,600 Not Implemented
CO0250 # 01 Y:1992 01 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $4,930 $167,000 Implemented
KU0379 # 10 Y:1992 10 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $162 $600 Not Implemented
SD0026 # 04 Y:1992 04 1992 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $4,723 $499 Implemented
CO0247 # 02 Y:1992 02 1992 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $2,990 $1,800 Implemented
IA0023 # 01 Y:1992 01 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $136,664 $13,000 n/a
MA0246 # 01 Y:1992 01 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,746 $3,614 Not Implemented
KU0372 # 04 Y:1992 04 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $35,349 $117,700 Not Implemented
KU0372 # 01 Y:1992 01 1992 USE MULTIPLE-EFFECT EVAPORATORS $133,326 $720,000 Not Implemented
UF0036 # 06 Y:1992 06 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $24,728 $42,000 Not Implemented
CO0245 # 08 Y:1992 08 1992 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $770 $3,100 Implemented
AS0055 # 03 Y:1992 03 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $6,959 $10,500 Not Implemented
KU0366 # 01 Y:1992 01 1992 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $3,148 $6,400 Not Implemented
MA0238 # 08 Y:1992 08 1992 MODERATE COOLING TOWER OUTLET TEMPERATURE $181 $100 Implemented
OR0144 # 01 Y:1992 01 1992 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $685 $0 Not Implemented