Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

43

matching recommendations
Reset
ARC 2.26 COOLING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0070 # 04 Y:1993 04 1993 UTILIZE A LESS EXPENSIVE COOLING METHOD $6,505 $15,000 Implemented
IA0072 # 02 Y:1993 02 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $42,651 $56,888 Not Implemented
GT0509 # 07 Y:1993 07 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,341 $21,050 Implemented
OR0193 # 07 Y:1993 07 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $8,806 $1,000 Implemented
OR0193 # 09 Y:1993 09 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $18,099 $39,000 Implemented
OR0191 # 05 Y:1993 05 1993 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $36,422 $41,000 Implemented
IA0071 # 11 Y:1993 11 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $310 $520 Not Implemented
OR0188 # 01 Y:1993 01 1993 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,784 $15,000 Implemented
WV0015 # 07 Y:1993 07 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,579 $1,400 Implemented
IA0065 # 06 Y:1993 06 1993 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $1,954 $10,280 Implemented
AS0097 # 06 Y:1993 06 1993 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $23,277 $88,239 Not Implemented
AS0096 # 06 Y:1993 06 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,455 $9,000 Not Implemented
NC0008 # 02 Y:1993 02 1993 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $3,254 $3,500 Not Implemented
AS0095 # 08 Y:1993 08 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,540 $7,500 Not Implemented
IA0061 # 02 Y:1993 02 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $68,521 $75,677 Not Implemented
CO0279 # 07 Y:1993 07 1993 MINIMIZE CONDENSER COOLING WATER TEMPERATURE $410 $240 Not Implemented
MO0097 # 06 Y:1993 06 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,468 $2,008 Not Implemented
AS0091 # 01 Y:1993 01 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,875 $3,800 Not Implemented
IA0056 # 02 Y:1993 02 1993 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $36,020 $56,799 Not Implemented
AS0088 # 11 Y:1993 11 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $704 $2,450 Not Implemented
GT0495 # 05 Y:1993 05 1993 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,390 $500 Implemented
OR0177 # 01 Y:1993 01 1993 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $8,536 $4,000 Implemented
IA0055 # 04 Y:1993 04 1993 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $11,960 $31,875 Not Implemented
AM0186 # 05 Y:1993 05 1993 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $7,460 $0 Implemented
OK0408 # 04 Y:1993 04 1993 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $2,789 $9,000 Not Implemented