Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

10,023

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0082 # 04 Y:2004 04 2004 AIR CONDITION ONLY SPACE NECESSARY $1,090 $0 Not Implemented
UD0706 # 08 Y:2004 08 2004 USE RADIANT HEATER FOR SPOT HEATING $1,883 $3,883 Not Implemented
BD0269 # 14 Y:2004 14 2004 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $236 $70 Implemented
LE0198 # 01 Y:2004 01 2004 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $20,168 $76,950 n/a
TA0081 # 07 Y:2004 07 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,035 $0 Implemented
BD0267 # 04 Y:2004 04 2004 USE RADIANT HEATER FOR SPOT HEATING $2,983 $4,250 Not Implemented
UM0265 # 01 Y:2004 01 2004 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $105,689 $64,000 n/a
AS0390 # 05 Y:2004 05 2004 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,779 $197 Implemented
MI0093 # 07 Y:2004 07 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $8,755 $510 Implemented
MS0259 # 09 Y:2004 09 2004 INSTALL TIMERS AND/OR THERMOSTATS $2,598 $0 Not Implemented
AS0388 # 06 Y:2004 06 2004 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $953 $1,400 Not Implemented
UM0264 # 01 Y:2004 01 2004 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $47,250 $2,600 Implemented
MA0560 # 02 Y:2004 02 2004 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $32,756 $23,710 Implemented
MA0562 # 03 Y:2004 03 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $3,445 $650 Implemented
OK0693 # 08 Y:2004 08 2004 INSTALL TIMERS AND/OR THERMOSTATS $772 $1,140 Implemented
AS0387 # 06 Y:2004 06 2004 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $9,180 $10,083 n/a
CO0550 # 06 Y:2004 06 2004 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,160 $23,870 Not Implemented
MI0091 # 02 Y:2004 02 2004 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $7,075 $150 Not Implemented
AM0470 # 12 Y:2004 12 2004 INSTALL TIMERS AND/OR THERMOSTATS $2,730 $270 Implemented
AM0470 # 15 Y:2004 15 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $960 $1,100 Implemented
AM0470 # 16 Y:2004 16 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $180 $400 Implemented
MS0258 # 11 Y:2004 11 2004 INSTALL TIMERS AND/OR THERMOSTATS $917 $236 Not Implemented
LL0203 # 04 Y:2004 04 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $526 $330 Not Implemented
LL0202 # 08 Y:2004 08 2004 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $442 $198 Not Implemented
GT0789 # 08 Y:2004 08 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $964 $2,900 Not Implemented