Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,704
matching recommendationsARC | 2.72 | SPACE CONDITIONING |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0189 # 03 Y:1996 | 03 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $932 | $2,080 | Implemented |
KG0067 # 03 Y:1996 | 03 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,761 | $600 | Implemented |
AS0189 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,466 | $4,200 | Implemented |
KG0067 # 05 Y:1996 | 05 | 1996 | AIR CONDITION ONLY SPACE NECESSARY | $987 | $0 | Implemented |
UL0168 # 05 Y:1996 | 05 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $459 | $200 | Not Implemented |
SF0098 # 06 Y:1996 | 06 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,634 | $4,600 | Implemented |
MA0374 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $3,185 | $1,720 | Implemented |
MS0066 # 04 Y:1996 | 04 | 1996 | AIR CONDITION ONLY SPACE NECESSARY | $4,606 | $282 | Not Implemented |
BD0067 # 01 Y:1996 | 01 | 1996 | USE RADIANT HEATER FOR SPOT HEATING | $8,237 | $7,500 | Not Implemented |
NC0103 # 03 Y:1996 | 03 | 1996 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $3,391 | $5,000 | Not Implemented |
NC0103 # 05 Y:1996 | 05 | 1996 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $3,167 | $530 | Implemented |
AS0188 # 04 Y:1996 | 04 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,409 | $9,450 | Implemented |
AS0187 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $716 | $1,750 | Not Implemented |
WI0277 # 04 Y:1996 | 04 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,365 | $9,500 | Implemented |
NV0062 # 06 Y:1996 | 06 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,419 | $3,575 | Not Implemented |
WI0277 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $6,122 | $1,600 | Not Implemented |
WI0277 # 10 Y:1996 | 10 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $248 | $700 | Not Implemented |
OD0069 # 05 Y:1996 | 05 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,088 | $380 | Not Implemented |
DS0064 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,273 | $600 | Implemented |
WV0100 # 04 Y:1996 | 04 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $753 | $4,725 | Not Implemented |
KG0066 # 05 Y:1996 | 05 | 1996 | AIR CONDITION ONLY SPACE NECESSARY | $2,569 | $1,150 | Not Implemented |
AS0186 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,586 | $16,140 | Implemented |
MA0372 # 01 Y:1996 | 01 | 1996 | INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS | $25,870 | $11,700 | Not Implemented |
GT0592 # 01 Y:1996 | 01 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $12,080 | $2,600 | Implemented |
AS0185 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $688 | $1,400 | Not Implemented |