Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

41

matching recommendations
Reset
ARC 2.11 FURNACES, OVENS AND DIRECTLY FIRED OPERATIONS
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LT0052 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $3,370 $1,220 Not Implemented
AT0054 # 07 Y:1986 07 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $644 $500 Implemented
LT0075 # 05 Y:1986 05 1986 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $532 $200 Implemented
LT0076 # 01 Y:1986 01 1986 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $6,000 $100 Not Implemented
LT0079 # 04 Y:1986 04 1986 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $4,361 $750 Implemented
ST0073 # 03 Y:1986 03 1986 INSTALL AUTOMATIC STACK DAMPER $7,099 $4,042 Implemented
KU0208 # 05 Y:1986 05 1986 INSTALL AUTOMATIC STACK DAMPER $655 $200 Implemented
KU0208 # 07 Y:1986 07 1986 INSTALL AUTOMATIC STACK DAMPER $317 $600 Implemented
OK0208 # 04 Y:1986 04 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $207 $78 Implemented
KU0207 # 17 Y:1986 17 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $160 $300 Implemented
KU0209 # 03 Y:1986 03 1986 INSTALL AUTOMATIC STACK DAMPER $19,573 $13,500 Not Implemented
ST0077 # 02 Y:1986 02 1986 INSTALL AUTOMATIC STACK DAMPER $878 $846 Implemented
GT0298 # 06 Y:1986 06 1986 CONTROL PRESSURE ON STEAMER OPERATIONS $7,600 $2,280 Not Implemented
ST0078 # 02 Y:1986 02 1986 INSTALL AUTOMATIC STACK DAMPER $2,122 $1,034 Not Implemented
ST0064 # 03 Y:1986 03 1986 INSTALL AUTOMATIC STACK DAMPER $605 $1,034 Not Implemented
KU0205 # 05 Y:1986 05 1986 INSTALL AUTOMATIC STACK DAMPER $1,085 $1,500 Not Implemented
KU0204 # 04 Y:1986 04 1986 INSTALL AUTOMATIC STACK DAMPER $1,220 $700 Implemented
KU0203 # 08 Y:1986 08 1986 INSTALL AUTOMATIC STACK DAMPER $303 $750 Implemented
KU0202 # 04 Y:1986 04 1986 INSTALL AUTOMATIC STACK DAMPER $702 $1,100 Not Implemented
CO0066 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $6,698 $6,000 Not Implemented
AT0045 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $12,817 $2,000 Not Implemented
ST0069 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $604 $150 Implemented
ST0061 # 05 Y:1986 05 1986 INSTALL AUTOMATIC STACK DAMPER $757 $1,410 Implemented
LT0062 # 06 Y:1986 06 1986 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $11,242 $0 Not Implemented
KU0197 # 04 Y:1986 04 1986 INSTALL AUTOMATIC STACK DAMPER $440 $700 Implemented